PORTABLE COLL-O-CRIMP® Model T-400-1 Set up and operating instructions
5 | PORTABLE COLL-O-CRIMP® Model T-400-1 Set up and operating instructions | 2022.10.
AQ430855066686en-000101
Cabinet Mounting Instructions
The FH-135X Stock Cabinet is designed specifically for your Coll-0-Crimp
hose service program. The Coll-O-Crimp® press T-400-1 and T-421 U electric
pump mount conveniently on top of the cabinet. If T-403-2 hand pump is
used, a mounting bracket with hardware (Part No. FH-136) is available. The
Coll¬0-Crimp unit can also be powered by the air driven hydraulic pump
T-402-1 with hand/foot treadle actuator which fits easily under the cabinet
for foot operation or mounts to surface for hand use.
The FH-135X cabinet has 50 heavy duty plastic drawers which
divide into one, two, three or four compartments providing
ample space for a large selection of hose ends and adapters.
!
CAUTION
It is recommended these instructions be read thoroughly
prior to set up, then used as a guide during actual assembly.
STEP 1 & 2:
Attach legs with bolts, nuts and washers provided. Then label
cabinet using the layout guide provided.
STEP 3:
Mount T-400-1 Press on top left of cabinet. Predrilled holes align the
press. Insert bolts from top of cabinet. Washers and nuts are threaded from
underneath. Tighten.
STEP 4:
T-421U Electric Pump. Mount on top right side of cabinet. Predrilled
holes align the pump. Insert bolts from top of cabinet. Washers and nuts are
installed from underneath. Tighten.
STEP 4a:
T-402-2 Air/Hydraulic Pump. Mount on top right side of cabinet
(see step 4) or place on the floor for easy foot pedal operation.
STEP 4b:
T-403-2 Hand Pump. Mount on top right of cabinet (see step 4) by
installing the FH-136 mounting bracket.
STEP 5:
Remove plug from middle port on top of press.
STEP 6:
Locate press/pump connecting hose assembly and remove
4315X6X8 For-Seal adapterfrom hose assembly. Thread into port on press
(from Step 5) and tighten.
STEP 7:
Remove plug from port on pump. (See page 2 for illustration of
appropriate pump connecting port).
Electric Pump (T-421U):
Remove 4315X6X8 For-Seal adapter from hose
assembly (T-400-16) and thread into the top middle port of pump and
tighten. Connect hose assembly to pump and press.
Air/Hydraulic Pump (T-402-1):
Remove 4315X6X8 For-Seal adapterfrom
hose assembly (T-400-18) and thread into middle port of press. Thread
4205X6X6 For-Seal adapter into the female 3/8” NPTF hydraulic swivel
connector of the air pump. Connect (T-400-18) assembly to press and
pump.
Hand Pump (T-403-2):
Remove 4315X6X8 For-Seal adapter from hose
assembly (T-400-19) and thread into middle port of press. Thread 4205X6X6
For-Seal adapter into rear port of pump. Connect hose assembly to press
and pump.
Summary of Contents for Weatherhead Coll-0-Crimp T-400-1
Page 1: ......