PORTABLE COLL-O-CRIMP® Model T-400-1 Set up and operating instructions
10 | PORTABLE COLL-O-CRIMP® Model T-400-1 Set up and operating instructions | 2022.10.
AQ430855066686en-000101
Operating Instructions (Con’t)
Figure B
COLL-O-CRIMP® Spacer Ring
Typical spacer ring illustrating both sides of ring.
Figure C
Nominal Crimp Diameter Measurement
Measuring crimp diameters should be a part of the normal hose assembly procedure. To insure a proper
crimp diameter reading, follow these steps:
1.
Measure the diameter in the middle of crimped portion of the hose end.
2.
Place the caliper in a postion to allow a measurement across the pressed (flat) portion of the crimp.
!
NOTE:
In the larger sizes, calipers may
be used; however, in the smaller sizes, and in
the “E” Series thermoplastic hose ends, a point
micrometer will provide an accurate reading.
Figure A
Insertion Depth
Place hose ends on hose until hose is bottomed
in collar.
To insure that hose is bottomed in collar, markthe
insertion depth on the hose before inserting it into
the hose end. On aluminum hose ends, hose is
bottomed when hose is visible in viewing hole in
collar.
Hose
Size
"U" Series
Rubber
"E" Series
Nylon/Teflon
069
"E" Series
Truck Hose
757 ‘E’ Series
Refrigerant
Hose
3/16
—
7/8
1
—
1/4
1-1/2
7/8
1
—
5/16
—
15/16
1-3/32
1
3/8
1-7/16
15/16
—
—
13/32
—
—
1-3/32
1-1/8
1/2
1-7/16
1-1/16
1-3/32
1-3/32
5/8
1-15/16
—
1-5/16
1-3/32
3/4
2-1/8
1-1/4
—
—
7/8
—
—
1-5/16
—
1
2-3/16
1-11/32
—
—
1-1/8
—
—
1-3/8
—
1-1/4
2-5/16
—
—
—
Summary of Contents for Weatherhead Coll-0-Crimp T-400-1