1.1.2 Coverage
This instruction covers 3 different drive sizes with single
phase 208-240 V power supply matching compressor sizes
for
-
13 kW/3 t cooling capacity
-
16 kW/4 t cooling capacity
-
20 kW/5 t cooling capacity
from software version 1.09.
1.2 Safety Instructions
1.2.1 High Voltage Warning
WARNING
The voltage of the variable speed drive is dangerous
whenever it is connected to mains. Incorrect installation of
the variable speed drive may cause damage to the
equipment, serious injury or death. Consequently, it is
essential to comply with the instructions in this manual as
well as local and national rules and safety regulations.
1.2.2 Safety Instructions
•
Make sure the drive is properly connected to
earth
•
Do not remove the mains connector or motor
(compressor) connector while the drive is
connected to power
•
Protect personnel against supply voltage
•
Protect the variable speed drive against over-
current according to national and local
regulations
•
The earth leakage current exceeds 3.5 mA
•
A stop command does not disconnect power
from the drive
1.3 Approvals
The drive has been designed/approved in accordance with
the following standards:
Safety
UL/EN 60335-1, 60335-2-34 (UL 984)
Household
UL/EN 60730
Industrial
EN 61800-3 (frequency converter standard)
Software
UL 1998 cl. B
Polymerics
UL 746 C
EMC
With ferrite: EN 55011 cl. A, EN 55014
Harmonics
EN 61000-3-12, IEEE 519-1992
Surge
EN 61642-12
Immunity
EN 61000-6
Transient
EN 61000-4
Corrosion
UL 50E, ISO 9223, EN 61000-5-1, ASTM B117
Environment IEC 60721-3-3 cl. 3K4
Enclosure
NEMA 250-2003
Table 1.1 Standards Complied to
The equipment complies with the flicker requirement according to
IEC/EN61000-3-11 at 230 V nominal voltage under the condition that
the service current capacity is
≥
100 A per phase or a maximum
permissible system impedance Z
MAX
= 0.1892
Ω