![Danfoss VLT HVACDrive Instruction Manual Download Page 166](http://html1.mh-extra.com/html/danfoss/vlt-hvacdrive/vlt-hvacdrive_instruction-manual_3860104166.webp)
Lin
e P
o
wer
S
u
pp
ly 3 x
38
0–480
V AC
- Normal
ove
rl
o
ad 1
10% f
o
r 1
mi
nu
te
ad
ju
st
ab
le
fr
eq
ue
nc
y
dr
iv
e
Typi
cal Sha
ft Outpu
t [kW]
P11K
11
P15K
15
P18K
18.
5
P22K
22
P30
K
30
P3
7K
37
P45
K
45
P55
K
55
P7
5K
75
P9
0K
90
Typi
cal Sh
aft
Outp
ut
[HP
] at
460 V
15
20
25
30
40
50
60
75
100
12
5
IP
20 /
Ch
assis
(B3+4 and C3
+4 may
be
co
nv
er
ted
to I
P21 usi
ng
a
conve
rsio
n ki
t
(P
le
ase
con
tact Da
nfoss)
B3
B3
B3
B4
B4
B4
C3
C3
C4
C4
IP 21 / NEM
A
1
B1
B1
B1
B2
B2
C1
C1
C1
C2
C2
IP
55 / NEM
A
12
B1
B1
B1
B2
B2
C1
C1
C1
C2
C2
IP
66 / NEM
A
12
B1
B1
B1
B2
B2
C1
C1
C1
C2
C2
Out
p
u
t c
u
rr
en
t
Conti
nuo
us (3
x
3
80–43
9
V)
[A]
24
32
37.
5
44
61
73
90
106
147
17
7
Interm
ittent (
3 x
380
–439
V)
[A
]
26.
4
35
.2
41.
3
48.
4
67.
1
80.
3
99
117
162
19
5
Conti
nuo
us (3
x
4
40–48
0
V)
[A]
21
27
34
40
52
65
80
10
5
130
16
0
Interm
ittent (
3 x
440
–480
V)
[A
]
23.
1
29
.7
37.
4
44
61.
6
71.
5
88
116
143
17
6
Conti
nuo
us
kV
A (400 V AC) [
kV
A]
16.
6
22
.2
26
30.
5
42.
3
50.
6
62.
4
73.
4
102
12
3
Conti
nuo
us
kV
A 460 V AC) [kVA
]
16.
7
21
.5
27.
1
31.
9
41.
4
51.
8
63.
7
83.
7
104
12
8
Max. cab
le
size:
(li
ne p
ow
er,
mo
to
r,
br
ak
e)
[mm
2
/
AW
G]
2)
10/
7
35/
2
50/
1/
0
(B
4=
35
/2
)
95/
4/
0
120/
MCM2
50
W
ith
li
ne power disconne
ct switch i
nclude
d:
16
/6
35/
2
35
/2
70
/3/
0
185/
kcm
il350
Ma
x.
in
pu
t c
u
rr
en
t
Conti
nuo
us (3
x
3
80–43
9
V)
[A]
22
29
34
40
55
66
82
96
133
16
1
Interm
ittent (
3 x
380
–439
V)
[A
]
24.
2
31
.9
37.
4
44
60.
5
72.
6
90.
2
106
146
17
7
Conti
nuo
us (3
x
4
40–48
0
V)
[A]
19
25
31
36
47
59
73
95
118
14
5
Interm
ittent (
3 x
440
–480
V)
[A
]
20.
9
27
.5
34.
1
39.
6
51.
7
64.
9
80.
3
105
130
16
0
Max. p
re-fu
ses
1)
[A
]
63
63
63
63
80
10
0
125
160
250
25
0
En
vi
ro
nm
en
t
Estim
ated power l
oss
at
r
at
ed m
ax.
lo
ad
[W]
4)
278
39
2
46
5
525
698
73
9
843
1083
1384
1474
W
eight encl
os
ure IP
20
[kg]
12
12
12
23.
5
23.
5
23.
5
35
35
50
50
We
ig
ht e
ncl
osure
I
P
21
[kg
]
23
23
23
27
27
45
45
45
65
65
W
eight encl
os
ure IP
55
[kg]
23
23
23
27
27
45
45
45
65
65
We
ig
ht e
ncl
osure
I
P
66
[kg
]
23
23
23
27
27
45
45
45
65
65
Eff
ici
ency
3)
0.
98
0.
98
0.
98
0.
98
0.9
8
0.
98
0.9
8
0.9
8
0.
98
0.9
9
Tab
le 9.
4:
Li
ne P
ow
er Supp
ly
3 x
380–4
80
V
AC
9 Specifications
VLT
®
HVAC Drive Instruction Manual
9-4
MG.11.AB.22 - VLT
®
is a registered Danfoss trademark
9