37
20
13
B11
B12
37
B10 B09
20
12
G
B07
B08
20
B06 B05
N
V
R
B03
B04
P
B02 B01
Z
A
/Z
B
+5V
/B
GND
/A
A
+2
4V
B
GND
130BC998.10
Illustration 5.2 Connections for 5 V Incremental Encoder
Max. cable length 10 m.
Hiperface
®
encoder
U
s 7-12V (r
ed)
GND (blue)
+C
OS (pink)
REFC
OS (black)
+SIN (whit
e)
REFSIN (br
own)
Da
ta +RS 485 (g
ra
y)
Da
ta -RS 485 (g
reen)
1
2
3
12
7
5
4
6
8
9
10
11
130BA164.10
Illustration 5.3 Connections for Hiperface Encoder - 1
+RS485
+cos
-RS485
+sin
-sin
GND
7-12V
-cos
37
20
13
B11
B12
37
B10 B09
20
12
G
B07
B08
20
B06 B05
N
V
R
B03
B04
P
B02 B01
130BC999.10
1
Illustration 5.4 Connections for Hiperface Encoder - 2
Item
Description
1
Hiperface encoder
Table 5.6 Legend
5.3.3 Resolver Option MCB 103
The MCB 103 Resolver Option is used for interfacing
resolver motor feedback to the frequency converter.
Resolvers are used basically as motor feedback device for
permanent magnet brushless synchronous motors.
The resolver option kit comprises:
•
MCB 103 Resolver Option
•
Cable to connect customer terminals to control
card
Selection of parameters: 17-5x resolver Interface.
MCB 103 Resolver Option supports a various number of
resolver types.
Resolver Poles
17-50 Poles: 2 *2
Resolver Input
Voltage
17-51 Input Voltage: 2.0–8.0 Vrms *7.0Vrms
Resolver Input
Frequency
17-52 Input Frequency: 2–15 kHz
*10.0 kHz
Transformation ratio 17-53 Transformation Ratio: 0.1–1.1 *0.5
Secondary input
voltage
Max 4 Vrms
Secondary load
App. 10 k
Ω
Table 5.7 Resolver Option MCB 103 Specifications
Type Code and Selection Gui...
VLT
®
Decentral Drive FCD 302
78
MG04H102 - VLT
®
is a registered Danfoss trademark
5
5