2 Safety

The following symbols are used in this manual:

WARNING

Indicates a potentially hazardous situation that could
result in death or serious injury.

CAUTION

Indicates a potentially hazardous situation that could
result in minor or moderate injury. It can also be used to
alert against unsafe practices.

NOTICE

Indicates important information, including situations that
can result in damage to equipment or property.

2.1  Qualified Personnel

Correct and reliable transport, storage, installation,
operation, and maintenance are required for the trouble-
free and safe operation of the soft starter. Only qualified
personnel are allowed to install or operate this equipment.

Qualified personnel are defined as trained staff, who are
authorized to install, commission, and maintain equipment,
systems, and circuits in accordance with pertinent laws and
regulations. Also, the qualified personnel must be familiar
with the instructions and safety measures described in this
installation guide.

2.2  General Warnings

WARNING

ELECTRICAL SHOCK HAZARD

VLT

®

 Soft Starter MCD 500 contains dangerous voltages

when connected to mains voltage. Only a qualified
electrician should carry out the electrical installation.
Improper installation of the motor or the soft starter can
cause death, serious injury, or equipment failure. Follow
the guidelines in this manual and local electrical safety
codes.
Models MCD5-0360C ~ MCD5-1600C:
Treat the busbar and heat sink as live parts whenever
the unit has mains voltage connected (including when
the soft starter is tripped or waiting for a command).

WARNING

PROPER GROUNDING

Disconnect the soft starter from mains voltage before
carrying out repair work.
It is the responsibility of the person installing the soft
starter to provide proper grounding and branch circuit
protection according to local electrical safety codes.
Do not connect power factor correction capacitors to the
output of the VLT

®

 Soft Starter MCD 500. If static power

factor correction is employed, it must be connected to
the supply side of the soft starter.

WARNING

IMMEDIATE START

In auto-on mode, the motor can be controlled remotely
(via remote inputs) while the soft starter is connected to
mains.
MCD5-0021B ~ MCD5-961B:
Transportation, mechanical shock, or rough handling
may cause the bypass contactor to latch into the On
state.

To prevent the motor from starting immediately on first
commissioning or operation after transportation:

Always ensure that the control supply is applied
before the power.

Applying control supply before power ensures
that the contactor state is initialized.

WARNING

UNINTENDED START

When the soft starter is connected to AC mains, DC
supply, or load sharing, the motor can start at any time.
Unintended start during programming, service, or repair
work can result in death, serious injury, or property
damage. The motor can start with an external switch, a
fieldbus command, an input reference signal from the
LCP or LOP, via remote operation using MCT 10 Set-up
Software, or after a cleared fault condition.

To prevent unintended motor start:

Press [Off/Reset] on the LCP before
programming parameters.

Disconnect the soft starter from the mains.

Completely wire and assemble the soft starter,
motor, and any driven equipment before
connecting the soft starter to AC mains, DC
supply, or load sharing.

Safety

Installation Guide

MG17M202

Danfoss A/S © 05/2017 All rights reserved.

5

2

2

Summary of Contents for VLT Compact Starter MCD 201

Page 1: ...ENGINEERING TOMORROW Installation Guide EtherNet IP Module VLT Compact Starter MCD 201 MCD 202 VLT Soft Starter MCD 500 vlt drives danfoss com...

Page 2: ......

Page 3: ...2 2 Cables 9 4 2 3 EMC Precautions 9 4 2 4 Network Establishment 9 4 3 Addressing 9 5 Device Configuration 10 5 1 On board Web Server 10 5 2 Ethernet Device Configuration Tool 10 6 Operation 12 6 1 De...

Page 4: ...19 8 Network Design 20 8 1 Star Topology 20 8 2 Line Topology 20 8 3 Ring Topology 20 8 4 Combined Topologies 21 9 Specifications 22 Index 23 Contents EtherNet IP Module 2 Danfoss A S 05 2017 All rig...

Page 5: ...herNet IP standard EtherNet IP provides users with the network tools to deploy standard Ethernet technology for manufacturing applications while enabling internet and enterprise connec tivity EtherNet...

Page 6: ...Light emitting diode PC Personal computer PLC Programmable logic controller Table 1 1 Symbols and Abbreviations Conventions Numbered lists indicate procedures Bullet lists indicate other information...

Page 7: ...Disconnect the soft starter from mains voltage before carrying out repair work It is the responsibility of the person installing the soft starter to provide proper grounding and branch circuit protec...

Page 8: ...cause a stopped motor to start To provide safety of personnel and equipment control the isolation device through an external safety system NOTICE Before changing any parameter settings save the curren...

Page 9: ...munication port slot B 4 Push in the top and bottom retaining clips to secure the module to the soft starter C 5 Connect Ethernet port 1 or port 2 on the module to the network 6 Apply control power to...

Page 10: ...OR MCD 500 ONLY Control via the fieldbus communication network is always enabled in local control mode and can be enabled or disabled in remote control mode parameter 3 2 Comms in Remote See the VLT S...

Page 11: ...e controller must establish communication directly with each device before the device can participate in the network 4 3 Addressing Each device in a network is addressed using a MAC address and an IP...

Page 12: ...ustration 5 1 Entering Network Settings 5 Edit the settings as required 6 Click Submit to save the new settings 6a To store the settings permanently in the module tick Set permanently 7 If prompted en...

Page 13: ...ected devices 177HA641 10 Illustration 5 3 The Tool Shows the Connected Devices 6 To set a static IP address click Configure and select Set IP address 177HA642 10 Illustration 5 4 Setting a Static IP...

Page 14: ...n size and type INT 177HA660 10 Illustration 6 1 Module Definition of the EtherNet IP Module Using RSLogix 5000 6 3 LEDs LED name LED status Description 1 2 T X R X 2 T X R X 1 L i n k 2 L i n k 1 E r...

Page 15: ...mote inputs and fieldbus communications a control command should be immediately followed by a status query to confirm that the command has been actioned 7 2 Control Commands Write Only NOTICE To opera...

Page 16: ...g state 4 Starting or running 5 Soft stopping 7 Trip 8 Jog forward 9 Jog reverse 2 3 0 15 Trip warning code See trip codes in Table 7 4 41 0 7 Motor current low byte Current A 51 0 7 Motor current hig...

Page 17: ...s all 3 phases 14 15 Reserved 20 21 0 13 Current motor FLC 14 15 Reserved 22 0 7 Motor 1 thermal model 23 0 7 Motor 2 thermal model 24 255 0 11 Power 12 13 Power scale 14 15 Reserved 26 0 7 power fact...

Page 18: ...7 3 These registers are not directly accessible via fieldbus Register Description Bits Details 0 Version 0 5 Binary protocol version number 6 8 Product parameter list version 9 15 Product type code 1...

Page 19: ...erved 19 31 Reserved Table 7 3 Functions of Internal Registers 1 Product type code 4 MCD 200 5 MCD 500 2 Reading register 3 changed parameter value resets registers 2 changed parameter number and 4 pa...

Page 20: ...2 1 Phase Sequence the options are 1 3 on the LCP but 0 2 via the module 7 6 Trip Codes Code Trip type MCD 201 MCD 202 MCD 500 0 No trip 11 Input A trip 20 Motor overload 21 Heat sink overtemperature...

Page 21: ...Px 83 Low Control Volts 84 98 Internal fault X Contact the local supplier with the fault code X Table 7 5 Internal Fault Code Associated with Trip Code 104 NOTICE Only available on VLT Soft Starters...

Page 22: ...r from the soft starter for the switch to operate NOTICE If the connection between 2 devices is interrupted the controller cannot communicate with devices after the interruption point NOTICE Each conn...

Page 23: ...gies A single network can include both star and line components 177HA631 10 Illustration 8 4 Combined Star Line Network Topology Network Design Installation Guide MG17M202 Danfoss A S 05 2017 All righ...

Page 24: ...gs IP address Automatically assigned configurable Device name Automatically assigned configurable Network Link speed 10 Mbps 100 Mbps auto detect Full duplex Auto crossover Power Consumption steady st...

Page 25: ...et attribute 10 H Heat sink 5 I Inputs Remote 5 Installing EtherNet IP option 7 Intended use 3 IP address 9 12 22 L LED Description 12 LED 4 Name 12 Status 12 M MAC address 9 Motor connection 6 N Netw...

Page 26: ...ucts already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trademarks in this material are property of the resp...

Reviews: