6.5.4 PROFINET-specific Parameter List
Parameter
Default value
2 set-up
Change during
operation
Conversion
index
Data type
Parameter 0-37 Display Text 1
0
1 set-up
TRUE
0
Visible string 21
Parameter 8-01 Control Site
[0] Dig. & ctrl. word
All set-ups
TRUE
–
Uint8
Parameter 8-02 Control Source
–
All set-ups
TRUE
–
Uint8
Parameter 8-03 Control Timeout Time
1
1 set-up
TRUE
-1
Uint16
Parameter 8-04 Control Timeout Function
[0] Off
1 set-up
TRUE
–
Uint8
Parameter 8-07 Diagnosis Trigger
[0] Disable
1 set-up
TRUE
–
Uint8
Parameter 8-10 Control Word Profile
[0] FC profile
All set-ups
TRUE
–
Uint8
Parameter 8-14 Configurable Control Word
CTW
[1] Profile default
All set-ups
TRUE
–
Uint8
Parameter 8-19 Product Code
–
1 set-up
TRUE
0
Uint32
Parameter 8-50 Coasting Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-51 Quick Stop Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-52 DC Brake Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-53 Start Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-54 Reversing Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-55 Set-up Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-56 Preset Reference Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-57 Profidrive OFF2 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-58 Profidrive OFF3 Select
[3] Logic OR
All set-ups
TRUE
–
Uint8
Parameter 8-90 Bus Jog 1 Speed
100 RPM
All set-ups
TRUE
0
Uint16
Parameter 8-91 Bus Jog 2 Speed
200 RPM
All set-ups
TRUE
0
Uint16
Parameter 9-07 Actual Value
0 N/A
All set-ups
FALSE
0
Uint16
Parameter 9-15 PCD Write Configuration
–
1 set-up
TRUE
–
Uint16
Parameter 9-16 PCD Read Configuration
–
1 set-up
TRUE
–
Uint16
Parameter 9-22 Telegram Selection
[100] None
1 set-up
TRUE
–
Uint8
Parameter 9-23 Parameters for Signals
[0]
All set-ups
TRUE
–
Uint16
[1] Enabled
1 set-up
FALSE
–
Uint16
Parameter 9-28 Process Control
[1] Enable cyclic master
1 set-up
FALSE
–
Uint16
Parameter 9-53 Profibus Warning Word
0
All set-ups
TRUE
0
V2
Parameter 9-65 Profile Number
0
All set-ups
TRUE
0
Oct. string 2
Parameter 9-70 Edit Set-up
[9] Active set-up
1 set-up
TRUE
–
Uint8
Parameter 9-71 Profibus Save Data Values
[0] Off
All set-ups
TRUE
–
Uint8
Parameter 9-72 ProfibusDriveReset
[0] No action
1 set-up
FALSE
–
Uint8
Parameter 9-80 Defined Parameters (1)
0
All set-ups
FALSE
0
Uint16
Parameter 9-81 Defined Parameters (2)
0
All set-ups
FALSE
0
Uint16
Parameter 9-82 Defined Parameters (3)
0
All set-ups
FALSE
0
Uint16
Parameter 9-83 Defined Parameters (4)
0
All set-ups
FALSE
0
Uint16
Parameter 9-84 Defined Parameters (5)
0
All set-ups
FALSE
0
Uint16
Parameter 9-85 Defined Parameters (6)
0
All set-ups
FALSE
0
Uint16
Parameter 9-90 Changed Parameters (1)
0
All set-ups
FALSE
0
Uint16
Parameter 9-91 Changed Parameters (2)
0
All set-ups
FALSE
0
Uint16
Parameter 9-92 Changed Parameters (3)
0
All set-ups
FALSE
0
Uint16
Parameter 9-93 Changed Parameters (4)
0
All set-ups
FALSE
0
Uint16
Parameter 9-94 Changed Parameters (5)
0
All set-ups
FALSE
0
Uint16
Parameter 12-00 IP Address Assignment
[10] DCP
1 set-up
TRUE
–
Uint8
Parameter 12-01 IP Address
0
1 set-up
TRUE
–
Oct. string 4
Parameter 12-02 Subnet Mask
0
1 set-up
TRUE
–
Oct. string 4
Parameter 12-03 Default Gateway
0
1 set-up
TRUE
–
Oct. string 4
Parameter 12-04 DHCP Server
0
1 set-up
TRUE
–
Oct. string 4
–
All set-ups
TRUE
–
Time diff. w/date
Parameters
PROFINET
36