8-54 Reversing Select
Select the trigger for the reversing function.
Option:
Function:
[3] Logic OR
The fieldbus/serial communication port or a
digital input triggers the reversing function.
8-55 Set-up Select
Select the trigger for the set-up selection.
Option:
Function:
[0]
Digital input A digital input triggers the set-up selection.
[1]
Bus
A serial communication port or the fieldbus
triggers the set-up selection.
[2]
Logic AND
The fieldbus/serial communication port and a
digital input trigger the set-up selection.
[3]
*
Logic OR
The fieldbus/serial communication port or a
digital input triggers the set-up selection.
8-56 Preset Reference Select
Option:
Function:
Select the trigger for the preset reference
selection.
[0]
Digital
input
A digital input triggers the preset reference
selection.
[1]
Bus
A serial communication port or the fieldbus
triggers the preset reference selection.
[2]
Logic AND
The fieldbus/serial communication port and a
digital input trigger the preset reference
selection.
[3]
*
Logic OR
The fieldbus/serial communication port or a
digital input triggers the preset reference
selection.
8-57 Profidrive OFF2 Select
Option:
Function:
[0]
Digital input
[1]
Bus
[2]
Logic AND
[3]
*
Logic OR
8-58 Profidrive OFF3 Select
Option:
Function:
[0]
Digital input
[1]
Bus
[2]
Logic AND
[3]
*
Logic OR
6.2.4 8-9* Bus Feedback
Use the parameter group to configure the bus feedback.
8-90 Bus Jog 1 Speed
Range:
Function:
100 RPM
*
[ 0 - 1500
RPM]
Enter the jog speed. Activate this
fixed jog speed via the serial port or
fieldbus option.
8-91 Bus Jog 2 Speed
Range:
Function:
200 RPM
*
[ 0 - 1500
RPM]
Enter the jog speed. Activate this
fixed jog speed via the serial port or
fieldbus option.
6.3 Parameter Group 9-** PROFIdrive
9-07 Actual Value
Range:
Function:
0
*
[0 - 65535 ] This parameter delivers the MAV for a Master
Class 2. This parameter is valid if the control
priority is set to Master Class 2.
9-15 PCD Write Configuration
Array [10]
Option: Function:
Select the parameters to be assigned to PCD 3–10 of
the telegrams. The number of available PCDs depends
on the telegram type. The values in PCD 3–10 are then
written to the selected parameters as data values.
Alternatively, specify a standard PROFIBUS telegram in
parameter 9-22 Telegram Selection
.
9-16 PCD Read Configuration
Array [10]
Option: Function:
Select the parameters to be assigned to PCD 3–10 of
the telegrams. The number of available PCDs depends
on the telegram type. PCDs 3–10 contain the actual
data values of the selected parameters. For standard
PROFIBUS telegram, see
parameter 9-22 Telegram
Selection
.
9-22 Telegram Selection
Option:
Function:
This parameter shows the selected
standard PROFIBUS telegram that
the PROFINET IO controller has sent
to the frequency converter. At
power-up, or if a non-supported
telegram is sent from the IO
controller, this parameter shows
None
in the display.
[1]
Standard telegram
1
Parameters
PROFINET
28
Danfoss A/S © 04/2017 All rights reserved.
MG06G102
6
6