10.1.5 Mains Supply 3 x 380 - 480V AC
Mains
Supply
3
x
380
-
480V
AC
-
Normal
overload
110%
for
1
minute
Frequency
converter
Typical
Shaft
Output
[kW]
PK37
0.37
PK55
0.55
PK75
0.75
P1K1
1.1
P1K5
1.5
P2K2
2.2
P3K0
3
P4K0
4
P5K5
5.5
P7K5
7.5
Typical
Shaft
Output
[HP]
at
460V
0.5
0.75
1.0
1.5
2.0
2.9
4.0
5.3
7.5
10
IP20
/
NEMA
Chassis
A2
A2
A2
A2
A2
A2
A2
A2
A3
A3
IP21
/
NEMA
1
IP55
/
NEMA
12
A5
A5
A5
A5
A5
A5
A5
A5
A5
A5
IP66
A5
A5
A5
A5
A5
A5
A5
A5
AA
A5
Output
current
130BA058.10
Continuous
(3
x
380-440V)
[A]
1.3
1.8
2.4
3
4.1
5.6
7.2
10
13
16
Intermittent
(3
x
380-440V)
[A]
1.43
1.98
2.64
3.3
4.5
6.2
7.9
11
14.3
17.6
Continuous
(3
x
441-480V)
[A]
1.2
1.6
2.1
2.7
3.4
4.8
6.3
8.2
11
14.5
Intermittent
(3
x
441-480V)
[A]
1.32
1.76
2.31
3.0
3.7
5.3
6.9
9.0
12.1
15.4
Continuous
kVA
(400V
AC)
[kVA]
0.9
1.3
1.7
2.1
2.8
3.9
5.0
6.9
9.0
11.0
Continuous
kVA
(460V
AC)
[kVA]
0.9
1.3
1.7
2.4
2.7
3.8
5.0
6.5
8.8
11.6
Max.
cable
size:
(mains,
motor,
brake)
[[mm
2
/
AWG]
2)
4/10
Max.
input
current
130BA057.10
Continuous
(3
x
380-440V
)
[A]
1.2
1.6
2.2
2.7
3.7
5.0
6.5
9.0
11.7
14.4
Intermittent
(3
x
380-440V
)
[A]
1.32
1.76
2.42
3.0
4.1
5.5
7.2
9.9
12.9
15.8
Continuous
(3
x
441-480V)
[A]
1.0
1.4
1.9
2.7
3.1
4.3
5.7
7.4
9.9
13.0
Intermittent
(3
x
441-480V)
[A]
1.1
1.54
2.09
3.0
3.4
4.7
6.3
8.1
10.9
14.3
Max.
pre-fuses
1)
[A]
10
10
10
10
10
20
20
20
30
30
Environment
Estimated
power
loss
at
rated
max.
load
[W]
4)
35
42
46
58
62
88
116
124
187
255
Weight
enclosure
IP20
[kg]
4.7
4.7
4.8
4.8
4.9
4.9
4.9
4.9
6.6
6.6
Weight
enclosure
IP21
[kg]
Weight
enclosure
IP55
[kg]
13.5
13.5
13.5
13.5
13.5
13.5
13.5
13.5
14.2
14.2
Weight
enclosure
IP66
[kg]
13.5
13.5
13.5
13.5
13.5
13.5
13.5
13.5
14.2
14.2
Efficiency
3)
0.93
0.95
0.96
0.96
0.97
0.97
0.97
0.97
0.97
0.97
Table
10.5
Mains
Supply
3
x
380
-
480V
AC
-
Normal
Overload
110%
for
1
Minute
Specifications
VLT
®
AQUA Drive
Operating Instructions
MG.20.M8.02 - VLT
®
is a registered Danfoss trademark
71
10
10