PVED-CC series 5 for PVG 32 technical data
PVED-CC control specification
Description
Type
Value
Supply Voltage (UDC)
Nominal
11 to 32 VDC
Minimum
9 V
Maximum
36 V
Current consumption
@ 12 V
560 mA
@ 24 V
300 mA
Power consumption
@ 12 V
6.2 W
@ 24 V
7.2 W
PVED-CC operating conditions
Description
Type
Value
Pilot Pressure
Nominal
13.5 bar [196 psi]
Minimum
10.0 bar [145 psi]
Maximum
15.0 bar [218 psi]
Oil Consumption
Neutral
0 l/min [0 US gal/min]
Locked Position
0 l/min [0 US gal/min]
Actuating
0.7 l/min [0.184 US gal/min]
Storage Temperature
Ambient
-40 to +90°C [-40 to +194°F]
Operating Temperature
Ambient
-30 to +60°C [-22 to +140°F]
Oil Viscosity
Operating Range
12 – 75 cSt [65 – 347 SUS]
Minimum
4 cSt [39 SUS]
Maximum
460 cSt [2128 SUS]
Oil Cleanliness
Maximum
18/16/13 (according to ISO 4406)
Grade of enclosure
IP 66
Service and Parts Manual
PVG 16/32/128/256
Installation
©
Danfoss | October 2018
AX284661889190en-000101 | 33
Summary of Contents for PVG 128
Page 1: ...Service and Parts Manual Proportional Valve Group PVG 16 32 128 256 www danfoss com ...
Page 141: ...Service and Parts Manual PVG 16 32 128 256 Danfoss October 2018 AX284661889190en 000101 141 ...
Page 142: ...Service and Parts Manual PVG 16 32 128 256 142 Danfoss October 2018 AX284661889190en 000101 ...
Page 143: ...Service and Parts Manual PVG 16 32 128 256 Danfoss October 2018 AX284661889190en 000101 143 ...