PVG 16 Plug orientation
The plug/port orientation shows dimensions of assembled product based on number of PVB used and
data on mounting threads.
In particularly exposed applications,
protection in the form of screening
of the electrical actuator is recommended
Mounting thread:
M8 x min 10 mm or
5/16-18 x min 0,39 in
Torque:
PVS: 20 N•m [177 lbf•in]
PVSI: 40 N•m [354 lbf•in]
Mounting thread:
M8 x min 10 mm or
5/16-18 x min 0.39 in
Torque:
40 N•m [354 lbf•in]
L2
L1
In particularly exposed
applications, protection in
the form of screening of the
electrical actuator is
recommended
Dimensions
No. of PVB 16
1
2
3
4
5
6
7
8
9
10
11
12
L1
mm
74
114
154
194
234
274
314
354
394
434
474
514
[in]
[2.91]
[4.49]
[6.06]
[7.64]
[9.21]
[10.79]
[12.36]
[13.94]
[15.51]
[17.09]
[18.66]
[20.24]
L2
mm
140
189
213
262
311
336
385
434
458
507
551
576
[in]
[5.51]
[7.44]
[8.39]
[10.31]
[12.24]
[13.23]
[15.16]
[17.09]
[18.03]
[19.96]
[21.69]
[22.68]
Service and Parts Manual
PVG 16/32/128/256
Installation
12 |
©
Danfoss | October 2018
AX284661889190en-000101
Summary of Contents for PVG 128
Page 1: ...Service and Parts Manual Proportional Valve Group PVG 16 32 128 256 www danfoss com ...
Page 141: ...Service and Parts Manual PVG 16 32 128 256 Danfoss October 2018 AX284661889190en 000101 141 ...
Page 142: ...Service and Parts Manual PVG 16 32 128 256 142 Danfoss October 2018 AX284661889190en 000101 ...
Page 143: ...Service and Parts Manual PVG 16 32 128 256 Danfoss October 2018 AX284661889190en 000101 143 ...