PVE 128/256 PVE series 7 installation
PVEO Series
P
7
VEH/H-U/H-FLA Series 7
8 ±0.5 N•m
[70 ±4.4 lbf•in]
5 [0.2]
P006095
W
Warning
For safety reasons, the PVE actuator and interface components must be considered as one unit. Do not
try to disassemble under any circumstances.
PVG 128/256 PVE connector variants
1x4 DEUTSCH
1x6 DEUTSCH
1x4 DIN
2
3
4
1
1
2
3 4
5
6
1
2
3
4
Pin
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
PVEO
1x4 DEUTSCH
Udc_A
GND
GND
Udc_B
1x4 DIN
Udc_A
Udc_B
GND
PVEH
PVEH-U
1x4 DEUTSCH
Us
Error
GND
Udc
1x4 DIN
Udc
Us
Error
GND
PVEH-FLA
1x6 DEUTSCH
Us
Error
Float
GND
Udc
PVG 128/256 PVE control specifications
PVEO control specifications
Control specification
PVEO
Supply Voltage (Udc)
Rated
12 Vdc
24 Vdc
Range
11
→
15 Vdc
22
→
30 Vdc
Max. ripple
5%
5%
Service and Parts Manual
PVG 16/32/128/256
Installation
46 |
©
Danfoss | October 2018
AX284661889190en-000101
Summary of Contents for PVG 128