PVEP series 4 for PVG 32
Seals must be correctly set to successfully seal the connector.
PVEP/PVEP-F
5[0.20]
8±0.5 Nm
[70±4.4 lbf·in]
PVEP/PVEP-F
Be sure to protect the LVDT Pin and O-rings are in place during installation. Do not over torque.
The seal in the DEUTSCH connector and the use of 1.5 mm
2
lines in all connections are crucial for
correctly sealing the connector.
PVEP series 4 for PVG 32 pin layout
1x6 DEUTSCH
1
2
3 4
5
6
Pin layout
Type
Connector
Pin 1
Pin 2
Pin 3
Pin 4
Pin 5
Pin 6
PVEP
1x6 DEUTSCH
PWM_A
Error
PWM_B
No connection
Not used
Udc
PVEP series 4 for PVG 32 technical data
PVEP control specification
Description
Type
Value
Supply Voltage (UDC)
Range
11 to 32 VDC
Max. ripple
5%
Max. 5 min
36 V
Service and Parts Manual
PVG 16/32/128/256
Installation
30 |
©
Danfoss | October 2018
AX284661889190en-000101