© Danfoss | DCS (im) | 2022.07
5. Flow
The flow (Q
eff
) at various pressure (p
max
) can be
calculated with the following equation:
Q
eff
= Q
(th)
– [(Q
(th)
– Q (p
max
)) x (p / p
max
)]
The theoretical flow can be calculated with the
following equation:
V x n
Q
(th)
=
1000
At zero pressure the true flow equals the
theoretical flow Q
(th)
.
Q
(th)
:
Theoretical flow (l/min / gpm)
Q (p
max
): Flows at max . pressure (l/min and
gpm), see 4 .1-4 .4
p
max
:
Max pressure (barg / psig)
p:
Pressure (barg / psig)
V:
Displacement (cm
3
/ rev .)
n:
Motor speed (rpm)
5.1 PAH 2-6.3 typical flow curves at max pressure
12
10
8
6
4
2
0
rpm
PAH 2.0
PAH 4.0
PAH 6.3
l/min
70
0
90
0
11
00
13
00
15
00
17
00
18
00
3
2.5
2
1.5
1
0.5
0
rpm
PAH 2.0
PAH 4.0
PAH 6.3
gpm
70
0
90
0
11
00
13
00
15
00
17
00
18
00
12
10
8
6
4
2
0
rpm
PAH 2.0
PAH 4.0
PAH 6.3
l/min
70
0
90
0
11
00
13
00
15
00
17
00
18
00
3
2.5
2
1.5
1
0.5
0
rpm
PAH 2.0
PAH 4.0
PAH 6.3
gpm
70
0
90
0
11
00
13
00
15
00
17
00
18
00
Summary of Contents for PAH 2
Page 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Page 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Page 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...