Choice of material
.
Rubber
.
Plastic
.
Stainless steel
1.
.
Iron
.
Copper
.
Brass
.
Aluminium
Always use system components made
of corrosion proof materials
Non-corrosion proof materials
may cause damage
Choice of filter
2.
Install a 10 micron absolute filter with
pressure switch
< 10
m
m
abs.
> 10
m
m
Return filter with bypass valve and
poorer filterability than 10
m
will
damage the system
Filter location
3.
Locate the return filter in the return line
immediately before the tank
Placing the return filter upstream of the
final load may damage the pump
Pump location
4.
Pump always to be placed below water
surface level
Pump location above water surface
level will cause damage
Water supply
7.
System to be filled via filter
Filling system with unfiltered
water causes damage
6.
Pressure Relief valve
Pressure relief valve to be mounted
vertically or with vertical outlet and
connected to return hose or tank
Coupling the pressure relief valve outlet
directly to the pump inlet may damage
the pump
Suction conditions
5.
System to be dimensioned to provide
a suction pressure of the pump inlet of
max. 0.1 bar vacuum
Poor suction conditions will cause
malfunction and damage the pump
Design
74
180R9379 | AQ188686503004en-000801 | PAH 2-12.5 } 07.2022
Summary of Contents for PAH 2
Page 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Page 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Page 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...