Operation guide | Installation, Operation and Maintenance Manual for PAH 2-12.5 pumps
10
180R9379 | AQ188686503004en-000801 | PAH 2-12.5 | 07.2022
5.1 Important dimensions
Physical dimensions and connections of the
pump unit are described in appendix 1, Data
sheet .
5.2 Cleanliness
It is very important that the tubes and pipes are
completely clean
: no dirt, chips or burrs are
allowed .
Flush all piping before connecting the high-
pressure pump to ensure the system is clean .
Internal surfaces of the piping must not be
corroded . If dirt or rust is not removed, the pump
and the valves can be damaged . In worst case
the pump can be damaged beyond repair!
5.3 Fluid temperature
Before start-up, the fluid and pump housing
temperature must be within the specified
temperature range listed in appendix 1, Data
sheet .
5.4 Electrical data
Check voltage, current frequency and rated
power on the electric motor and VFD settings on
the name plate placed on both the motor and
the VFD .
5.5 Local regulations
Commissioning must always be done in
accordance with valid regulations and local
standards .
5.
Installation and
commissioning
Open system design
Closed system design
M
2
SYSTEM
1
4
5
5
6
7
3
PI
PI
8
Summary of Contents for PAH 2
Page 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Page 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Page 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...