![Danfoss PAH 2 Installation, Operation And Maintenance Manual Download Page 22](http://html1.mh-extra.com/html/danfoss/pah-2/pah-2_installation-operation-and-maintenance-manual_3788517022.webp)
Data sheet
PAH 2/4/6.3, PAH 10/12.5, PAH 20/25/32 and PAH 50/63/70/80/100 pumps
22 |
180R9379 | AQ188686503004en-000801 | PAH 2-12 .5
© Danfoss | DCS (im) | 2022.07
4.
Technical data
4.1 PAH 2-12.5
Pump size
2
4
6.3
10
12.5
Code number
180B0024
180B0022
180B0023
180B0008
180B0007
Code number ATEX
2)
180B6124
180B6122
180B6123
180B6108
180B6107
Housing material
AISI 304
AISI 304
AISI 304
AISI 304
AISI 304
Geometric
displacement
cm³/rev
2
4
6 .3
10
12 .5
in³/rev
0 .12
0 .24
0 .38
0 .60
0 .75
Pressure
Min . outlet
pressure
barg
10
10
10
10
10
psig
145
145
145
145
145
Max . outlet
pressure
barg
140
140
140
160
160
psig
2030
2030
2030
2320
2320
Inlet pressure,
continuous
barg
0-4
0-4
0-4
0-4
0-4
psig
0-58
0-58
0-58
0-58
0-58
Speed
Min . speed,
continuous
rpm
700
700
700
700
700
Max . speed
rpm
1800
1800
1800
1800
1800
Typical flow - Flow curves available in section 5
1000 rpm at
max . pressure
l/min
1 .0
3 .2
5 .6
8 .4
11 .0
1500 rpm at
max . pressure
l/min
2 .0
5 .2
8 .7
13 .4
17 .2
1200 rpm at
max . pressure
gpm
0 .4
1 .0
1 .8
2 .7
3 .5
1800 rpm at
max . pressure
gpm
0 .7
1 .7
2 .8
4 .3
5 .5
Typical motor size
1500 rpm at
max . pressure
kW
0 .9
1 .7
2 .6
4 .5
5 .6
1800 rpm at
max . pressure
hp
1 .5
2 .7
4 .2
7 .3
9 .0
Torque at max .
spec .
Nm
5 .9
10 .9
16 .7
29 .0
35 .8
lbf-ft
4 .4
8 .0
12 .3
21 .4
26 .4
Media
temperature
°C
2-50
2-50
2-50
2-50
2-50
°F
36-122
36-122
36-122
36-122
36-122
Ambient
temperature
°C
0-50
0-50
0-50
0-50
0-50
°F
32-122
32-122
32-122
32-122
32-122
Sound
pressure level
1)
dB(A)
76
76
76
75
75
Weight
kg
4 .4
4 .4
4 .4
7 .7
7 .7
lbs
9 .7
9 .7
9 .7
17 .0
17 .0
1)
Measurements according to EN ISO 3744: 2010 / dB(A) [L
PA, 1m
] values are calculated .
Measured at max pressure and rpm for a motor pump unit .
2)
Category 2, Zone 1 or Category 3, Zone 2 .
For certified pumps specifications on inlet and outlet pressure is stated on the 3 .1 inspection certificate and may
vary from generic specifications stated above .
Summary of Contents for PAH 2
Page 32: ... Danfoss DCS im 2022 07 AI073186502976en 001901 32 ...
Page 42: ... Danfoss DHS im 2022 02 180R9379 AQ188686503004en 000701 PAH 2 12 5 42 ...
Page 43: ...M a n u a l Electric Motors Motor Manual hoyermotors com ...
Page 47: ...47 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 79: ...79 180R9379 AQ188686503004en 000801 PAH 2 12 5 07 2022 ...
Page 80: ... Danfoss DCS im 2022 07 180R9379 AQ188686503004en 000801 PAH 2 12 5 80 ...