Instructions

Optyma™

 

Slim Pack 

OP-HPMP/HPZP/HPUS/LPZP/LPZS

1 | © Danfoss | DCS (CC)| 2017.03

FRCC.PI.051.A1.ML 

Summary of Contents for OP-HPMP

Page 1: ...English English p 4 Español Spanish p 9 Português do Brasil Brazilian Portuguese p 14 Instructions Optyma Slim Pack OP HPMP HPZP HPUS LPZP LPZS 1 Danfoss DCS CC 2017 03 FRCC PI 051 A1 ML ...

Page 2: ...880 525 327 361 Ø8 861 30 OP HPMP036 40 OP HPZP036 40 OP HPUS019 21 327 861 626 51 361 Ø8 525 30 OP HPMP019 28 OP HPZP019 28 OP HPUS015 LPZP048 68 Instructions 2 Danfoss DCS CC 2017 03 FRCC PI 051 A1 ML ...

Page 3: ...525 469 Ø8 1283 895 30 30 437 OP HPMP050 064 OP HPZP050 064 OP HPUS026 038 LPZP013 018 Instructions Danfoss DCS CC 2017 03 3 FRCC PI 051 A1 ML ...

Page 4: ...prightposition Store the unit between 35 C and 50 C Don t expose the packaging to rain or corrosive atmosphere After unpacking check that the unit is com plete and undamaged 3 Installation precautions Do not braze as long the condensing unit is under pressure Never place the unit in a flammable atmosphere Place the unit in such a way that it is not blocking orhinderingwalkingareas doors windowsors...

Page 5: ...nergize the unit It must start promptly If the compressor does not start check wiring conformity voltage on terminals and sequence phase Eventual reverse rotation of a 3 phase com pressor can be detected by following phe nomena unit doesn t start the compressor doesn t build up pressure it has abnormally high sound level and abnormally low power consumption In such case shut down the unit immediat...

Page 6: ...TER RL RELE RELAY V VENTILADOR FAN FUSÍVEL FUSIBLE FUSE C R 2 4 1 3 6 a2 5 a1 K PL PH 230V 1 50 60Hz PE RC F2 F3 CP S P PE 2 1 4 P L2 2 L1 V1 CV 1 2 5 CS CR RL 1 PE CV V2 F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIXA P...

Page 7: ... FAN FUSÍVEL FUSIBLE FUSE 2 4 1 3 6 a2 5 a1 K PL PH 230V 3 50 60Hz PE F2 F3 CP P PE 2 1 4 P L2 L3 2 L1 V1 CV 1 RC PE CV V2 SFF M1 L N M2 L1 L2 L3 S1 S2 R1 1 8KOhm DEP 101B F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIXA ...

Page 8: ...RANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIXA PRESOSTATO BAJA PRESSURE SWITCH LBP RC RESISTÊNCIA CARTER CALENTADOR CARTER CRANKCASE HEATER RL RELE RELAY V VENTILADOR FAN Code V HPMP HPZP LPZP Code V HPUS LPZS Danfoss can accept no responsibility for possible errors in catalogues b...

Page 9: ...Manipule la unidad con cuidado El embalaje admite el uso de una carretilla elevadora o una transpaleta para su manipulación Use siempre equipos de elevación adecuados y seguros Almacene y transporte la unidad en posición vertical Almacene la unidad a temperaturas compren didas entre 35 C y 50 C No exponga el embalaje a la lluvia o a atmósfe ras de carácter corrosivo Tras desembalar la unidad compr...

Page 10: ...y la fuente de ali mentación sean compatibles Compruebe que la resistencia de cárter se en cuentre en funcionamiento Compruebe que el ventilador pueda girar libre mente Compruebe que se haya retirado la chapa de pro tección de la parte posterior del condensador Equilibre las presiones de los lados HP y LP Ponga en marcha la unidad Debe arrancar de inmediato Si el compresor no se pone en mar cha co...

Page 11: ...ER RL RELE RELAY V VENTILADOR FAN FUSÍVEL FUSIBLE FUSE C R 2 4 1 3 6 a2 5 a1 K PL PH 230V 1 50 60Hz PE RC F2 F3 CP S P PE 2 1 4 P L2 2 L1 V1 CV 1 2 5 CS CR RL 1 PE CV V2 F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIXA PR...

Page 12: ...FAN FUSÍVEL FUSIBLE FUSE 2 4 1 3 6 a2 5 a1 K PL PH 230V 3 50 60Hz PE F2 F3 CP P PE 2 1 4 P L2 L3 2 L1 V1 CV 1 RC PE CV V2 SFF M1 L N M2 L1 L2 L3 S1 S2 R1 1 8KOhm DEP 101B F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIXA P...

Page 13: ...FAN FUSÍVEL FUSIBLE FUSE 5 6 2 4 1 3 6 a2 5 a1 K V2 CV PL PH 380V 3 50 60Hz PE F2 CP P PE 2 1 4 P L2 L3 1 2 L1 N V1 CV RC PE SFF M1 L N M2 L1 L2 L3 S1 S2 R1 1 8KOhm DEP 101B F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIX...

Page 14: ...pós desembalar certifique se de que a unidade esteja completa e intacta 3 Medidas de segurança antes da montagem Nãosoldeaunidadecondensadoraenquanto ela estiver pressurizada Nunca instale a unidade em atmosferas inflamáveis Instaleaunidadedemodoqueestanãobloqueie nem atrapalhe áreas de passagem portas janelas e afins Certifique se de que haja espaço suficiente ao redor da unidade para circulação ...

Page 15: ...ediatamente Em caso negativo verifique as fiações a tensão nos terminais e a fase de sequência A eventual rotação inversa de um compressor trifásico pode ser detectada pelos seguintes fenômenos a unidade não inicia o compressor não gera pressão apresenta nível de ruído mais alto e consumo de energia mais baixo do que os normais Neste caso desligue o aparelho imediatamente e conecte as fases nos re...

Page 16: ...ATER RL RELE RELAY V VENTILADOR FAN FUSÍVEL FUSIBLE FUSE C R 2 4 1 3 6 a2 5 a1 K PL PH 230V 1 50 60Hz PE RC F2 F3 CP S P PE 2 1 4 P L2 2 L1 V1 CV 1 2 5 CS CR RL 1 PE CV V2 F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIXA ...

Page 17: ... FAN FUSÍVEL FUSIBLE FUSE 2 4 1 3 6 a2 5 a1 K PL PH 230V 3 50 60Hz PE F2 F3 CP P PE 2 1 4 P L2 L3 2 L1 V1 CV 1 RC PE CV V2 SFF M1 L N M2 L1 L2 L3 S1 S2 R1 1 8KOhm DEP 101B F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAIXA ...

Page 18: ... FAN FUSÍVEL FUSIBLE FUSE 5 6 2 4 1 3 6 a2 5 a1 K V2 CV PL PH 380V 3 50 60Hz PE F2 CP P PE 2 1 4 P L2 L3 1 2 L1 N V1 CV RC PE SFF M1 L N M2 L1 L2 L3 S1 S2 R1 1 8KOhm DEP 101B F1 COMPRESSOR COMPRESOR CR CAPACITOR MARCHA RUN CS CAPACITOR ARRANQUE START CV CAPACITOR VENTILADOR FAN F CP FUSÍVEL FUSIBLE FUSE K CONTATOR CONTACTOR PH PRESSOSTATO ALTA PRESOSTATO ALTA PRESSURE SWITCH HBP PL PRESSOSTATO BAI...

Page 19: ...anfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterations can be made without subsequential changes being necessary in specifications already agreed All trade marks in this material are property of the respective companies Danfoss and the Danfoss logotype are trademarks of Danfoss A S All rights reserved ...