Safety technology: MCB14x Document No.:
MG34Y104
Rev.: 06 23 October 2012 Page 15 of 25
6.2.
Overview and name of connection terminals
InputsInputs
Operation Meaning
MCB140 terminal
MCB141 terminal
Channel
1
Channel
2
Channel
1
Channel
2
SS1
Safe Stop 1 (SS1)
Y32/8
Y32/9
11
16
SLS
Derated velocity operating mode
Y32/10
Y32/11
12
17
Door
Monitoring of protective interlock
Y32/12
Y32/13
13
18
Pr_1
Input for speed detection of Start/Stop
Y32/14
15
Pr_2
Initiator input for speed detection
Y32/15
20
FBC
Contactor (auxiliary contact) of drive energy
isolator
Y32/16
5
Table 13: Assignment of safety inputs
Safety-related outputs
Operation Meaning
MCB140 terminal MCB141 terminal
Ramp
Ramp signal for controlled drive shutdown
Y32/17
6
STO_O
Safe Torque Off (STO)
Y32/18
7
ExC
Control of drive energy isolator
Y32/5
8
SSO
Enabling of protective device
Y32/6
9
Table 14: Assignment of safety outputs
Non-safety-related outputs
Operation Meaning
MCB140 terminal MCB141 terminal
Diag
Multi-functional diagnostic output
Y32/7
10
Table 15: Assignment of diagnostic output
Diag is not integrated in the safety operation. Depending on the configuration, it can be used as a binary
signal output or analog speed output