Safety technology: MCB14x Document No.:
MG34Y104
Rev.: 06 23 October 2012 Page 22 of 25
Parameter description - Group P1
Parame
ter No.
Name
Setting value
Default
Notes
P 101
Input type SS1
Tripping of
emergency stop
NC/NC
NC/NC
Parameter definitions in Table 26
NC/NO
OSSD
PNP-NPN
NC-noP
P 102
Input type SLS
Monitoring of derated
working speed
NC/NC
NC/NC
Parameter definitions in Table 26
NC/NO
OSSD
PNP-NPN
NC-noP
NO/NO
NO-noP
P 103
Input type Door
Monitoring of
protective devices
NC/NC
NC/NC
Parameter definitions in Table 26
NC/NO
OSSD
PNP-NPN
NC-noP
P 104
Dual channel inputs
YES
YES
Single/dual channel use of inputs
No
P 105
Door interlock used
YES
YES
Use of protective interlock feedback
contact
No
P 106
Use of contactor
(auxiliary contact) for
FBC input
YES-d
YES-d
dynamically evaluated
YES-s
statically evaluated
Not
not used
P 107
Test pulses on
outputs
YES
YES
Superimposing of L-active pulses to test
the ability to derate the safety outputs
No
P 108
Use of DIAG function
output
FAout
FAout
Binary fault output
SSout
Output enabled at standstill
SIout
Analog speed output 4-20 mA
SUout
Analog speed output 2-10 V
P 109
SLS used
YES
YES
Use of operating mode selection switch
No
Table 22: Parameter group 1
A functional description of the setting values and input wiring are explained in Table 26
Parameter description - Group P2
No.
Name
Setting value
Default
Notes
P 201
Speed feedback
Speed detection
0
2
Speed detection disabled
1
1 initiator at channel 2
2
2 initiators
1-2dr
1 2-wire initiator at channel 2
1-EnA
1 initiator (channel 2), channel 1
enabled
P 202
Proximity switch
current
OFF
OFF
Switch on additional load for 2-wire
initiators
On
P 203
Pulses per revolution
1…50
1
P 204
Start-up delay
1…128s
4s
Only enabled if P201=1-Ena
Table 23: Parameter group 2