background image

070R9830

070R9830

OHJEET

KSV

520F0199   

DKBG.PI.14.A1.6T  01-12

Fig. 1

Fig. 2

Fig. 3

Tilausnro

SAFAG

Vanha

Danfoss

Uusi

Paine

Kapasiteetti

tilausnro

tilausnro

(bar)*

 (l/h)

KSA 400

071F2000

VBGRMMDC-3-S5030

070H4633

KSV 400

070H2100

6-25

400

KSA 400

071F2000

VBGRMMDC-4-S5030

070H4634

KSV 400

070H2000

15-40

400

KSA 400

071F2001

VBGRMMIC-3-S5030

070H4733

KSV 400

070H2101

6-25

400

KSA 400

071F2001

VBGRMMIC-4-S5030

070H4734

KSV 400

070H2001

15-40

400

KSA 630

071F2002

VBGRPDC-3-S5030

070H4643

KSV 630

070H2102

6-25

630

KSA 630

071F2002

VBGRPDC-4-S5030

070H4644

KSV 630

070H2002

15-40

630

KSA 630

071F2003

VBGRPIC-3-S5030

070H4743

KSV 630

070H2103

6-25

630

KSA 630

071F2003

VBGRPIC-4-S5030

070H4744

KSV 630

070H2003

15-40

630

KSA 1000

071F2004

VBGRMDC-3-S5030

070H4663

KSV 950

070H2104

6-25

950

KSA 1000

071F2004

VBGRMDC-4-S5030

070H4664

KSV 950

070H2004

15-40

950

KSA 1000

071F2005

VBGRMIC-3-S5030

070H4763

KSV 950

070H2105

6-25

950

KSA 1000

071F2005

VBGRMIC-4-S5030

070H4764

KSV 950

070H2005

15-40

950

KSA 1000

071F2004

VBGRGDC-3-S5030

070H4693

KSV 1100

070H2114

6-25

1100

KSA 1000

071F2004

VBGRGDC-4-S5030

070H4694

KSV 1100

070H2014

15-40

1100

KSA 1000

071F2005

VBGRGIC-3-S5030

070H4793

KSV 1100

070H2115

6-25

1100

KSA 1000

071F2005

VBGRGIC-4-S5030

070H4794

KSV 1100

070H2015

15-40

1100

* Jos asiakas ei ole ilmoittanut painealuetta, se valitaan väliltä 15 – 40 bar.

Tekniset tiedot

Viskositeettialue:

2,5 – 450 cSt.

Pyörimisnopeus:

Maks. 3600 kierr/min

-1

maksimipaine 25 bar
Maks. 2800 kierr/min

-1

maksimipaine 25-40 bar

Tehdassäätö:

Minimipaine

Öljyn lämpötila:

Maks. 180 °C

Maks. syöttöpaine: 5 bar

Liitäntäaukot

P = Suutin G 

1

/

2

S = Imujohto G 

1

/

2

R = Paluujohto G 

1

/

2

P

n

 = Paineenmittaus G 

1

/

4

P

s

 = Imu-/syöttöpaineen mittaus G 

1

/

4

Kaikissa liitännöissä on otsatiivistepinta vakio-
mallisille tiivisteille.
Kuvista 1 ja 2 ilmenee liitäntäaukkojen sijainti
oikealle (RH)ja vasemmalle (LH) pyörivissä
pumpuissa.

Tärkeää

KSV pumppu on tarkoitettu kaksiputkikäyttöön.
Yksiputkikäytössä, pumpun syöttöpaineen ollessa
positiivinen, tarvitaan ulkoinen ohitus paluuaukon ja
imuaukon välille.

Asennus

Laite on varustettava voimassaolevien määräysten
mukaisella esisuodattimella.

Väliaine

Pumppu on tarkoitettu käytettäväksi mineraalipohjai-
silla polttoöljyillä tai vastaavan/korkeamman luokan
väliaineilla.

Ensimmäinen käynnistys

Ennen käynnistystä: Varmista, että pumpun pyöri-
missuunta on oikea.
Varmista, että pumpussa on voiteluöljyä. Täytä
tarvittaessa.

Varmista, että imupuolen putkiliitännät ja putket
ovat ilmatiiviit.
Varmista minimi tyhjö ilmauksen aikana avaamalla
kaikki imupuolen venttiilit.
Avaa painepuolen aukko, käynnistä moottori ja ilmaa
sekä imujohto että pumppu, kunnes öljyvirrassa ei
ole enää ilmakuplia. Voit halutessasi käyttää läpinä-
kyvää muoviletkua. Sulje aukko.
Asenna manometri painepuolelle ja säädä öljynpaine
haluttuun lukemaan. Ks. kuva 3.
Varmista, että kaikki venttiilit ovat normaalissa
asennossa ja että poltin toimii moitteettomasti.
Pysäytä pumppu, irrota manometri ja käynnistä
pumppu uudelleen.

SUOMI

Säiliön liitäntä

Varmista, että imu- että paluuputki ovat öljynpinnan
alapuolella. Sijoita imuyhde sellaiselle korkeudelle,
jossa pohjasakka ei imeydy pumppuun (vähintään
10 cm pohjasta).
Sijoita paluuyhde riittävän kauaksi imuputkesta,
jotta paluuöljy ei pääse sekoittumaan imuun.
Säiliö- ja suodatinvalmistajat antavat asennus-
ohjeita ja DIN 4755 normista löytyy myös säiliön
asennusta koskevaa tietoa.

Lisävarusteet

Pumppua voi käyttää sekä kuljetus- että
syöttöpumppuna, jos siihen vaihdetaan
paineensäätöjousi. Jousi on tilattava erikseen.
KSV pumpussa on 

 6,5 

×

 42 liitäntä

kuumennuspatruunalle.

Lisävarusteet

Jännite

Tilausnro

Kaapelin pituus

Jousi. Painealue 1,0 – 4,0 bar

070H0000

Jousi. Painealue 2,0 – 9,0 bar

070H0001

Kuumennuspatruuna 125 W

230 V

070H0002

300 mm

Kuumennuspatruuna 125 W

230 V

070H0003

600 mm

Kuumennuspatruuna125 W

110 V

070H0004

450 mm

Kierteinen kaapeliliitin M8 

×

 1

070H0005

Öljypumppu VBGR (KSV)
Aukkomerkinnät

Siirtymäkaudella KSA 400, 630, 1000 –pumppuja
korvaavat VBGR ja KSV –merkinnällä varustetut
pumput. Ks. kaaviota.

Toiminto

Kierre

Danfoss-merkintä

SAFAG-merkintä

Imuaukko

1

/

2

S

A

Paineaukko

1

/

2

P

S

Paineenmittausaukko

1

/

4

Pn

Imupaineen mittausaukko

1

/

4

Ps

Paluuaukko

1

/

2

R

R tai

 

(BP)

Pyörimissuunta

RH (oikea)

LH (vasen)

DC (oikea)

IC (vasen)

VBGR pumppujen liitäntäaukot on varustettu nor-
maaleilla SAFAG-merkinnöillä.
KSV pumppujen aukot on varustettu normaaleilla
Danfoss-merkinnöillä.

Muutos KSA – KSV (VBGR)

Produced by Danfoss G1 advertising agency 01.12 FO-Bi.LG

Kuumenn-
uspatruuna

Summary of Contents for KSA 1000

Page 1: ...a of a corresponding or higher classification First time start Before starting the pumps the following points must be observed Check direction of rotation of the pump Secure that there is oil in the pump for lubrication at start otherwise fill up the pump with oil Make sure that all connections and pipes on the suction side are air tight Open all valves on suction side to create minimum vacuum at ...

Page 2: ...specificeret for drift med mineralske brændselsolier eller medier med tilsvarende eller højere klassifikation Førstegangs start Før pumpen startes skal følgende punkter under søges Check at omdrejningsretningen er rigtig Pumpen skal være fyldt med olie Hvis dette ikke er tilfældet skal pumpen fyldes Alle rørforbindelser og samlinger på sugesiden skal være lufttætte Åben alle ventiler på sugesiden ...

Page 3: ...iebnahme Bevor die Pumpe gestartet wird müssen folgende Punkte geprüft werden Überprüfen dass die Drehrichtung stimmt Die Pumpe muss mit Öl gefüllt sein Sollte dies nicht der Fall sein muss die Pumpe gefüllt werden Alle Rohrverbindungen und Verschraubungen auf der Saugseite müssen luftdicht ausgeführt sein Alle Ventile auf der Saugseite öffnen damit das Vakuum während der Entlüftung so niedrig wie...

Page 4: ...quivalente ou supérieure Premier démarrage Avant de démarrer une pompe vérifier et respecter les points suivants Vérifier le sens de rotation de la pompe Vérifier que la pompe contient du fioul Dans le cas contraire assurer son remplissage S assurer que la totalité des raccords et des tuyaux situés du côté de l aspiration sont étanches à l air Ouvrir toutes les vannes situées du côté de l aspirati...

Page 5: ...er som har mot svarande eller högre klassifikation Första start Innan pumpen startas skall följande punkter kontrolleras Kontrollera att pumpen har korrekt rotationsriktning Pumpen skall vara fylld med olja Om så inte är fallet skall pumpen fyllas Alla röranslutningar och skarvar på sugsidan skall vara lufttäta Öppna alla ventiler på sugsidan för att skapa min sta möjliga vakuum under urluftningen...

Page 6: ... corretto Accertarsi che la pompa sia piena d olio nel caso non lo fosse riempirla d olio Tutte le connessioni dei tubi ed i giunti sul lato di aspira zione devono essere a tenuta d aria Aprire tutte le valvole sul lato di aspirazione per creare un vuoto minimo al momento della messa in funzione iniziale Aprire una porta sul lato di mandata mettere in moto il motore e sfiatare la linea di aspirazi...

Page 7: ...te opstart Voordat de pomp gestart wordt moeten de vol gende punten onderzocht worden Controleer of de omwentelingsrichting de juiste is De pomp moet met olie gevuld zijn Indien dit niet het geval is moet de pomp met olie gevuld worden Alle buisaansluitingen en koppelingen op de zuig zijde moeten luchtdicht zijn Open alle kleppen op de zuigzijde om zo weinig mogelijk vacuüm op te wekken tijdens he...

Page 8: ...aine Pumppu on tarkoitettu käytettäväksi mineraalipohjai silla polttoöljyillä tai vastaavan korkeamman luokan väliaineilla Ensimmäinen käynnistys Ennen käynnistystä Varmista että pumpun pyöri missuunta on oikea Varmista että pumpussa on voiteluöljyä Täytä tarvittaessa Varmista että imupuolen putkiliitännät ja putket ovat ilmatiiviit Varmista minimi tyhjö ilmauksen aikana avaamalla kaikki imupuolen...

Page 9: ...kacji Pierwszy rozruch Przed za àczeniem pompy nale y upewniç si e kierunek obrotów pompy jest w aÊciwy sprawdziç czy pompa jest nape niona olejem i nape niç olejem jeÊli jest pusta sprawdziç e wszystkie po àczenia rurowe i z àczki po stronie ssawnej sà hermetycznie szczelne otworzyç wszystkie zawory po stronie ssawnej aby do minimum ograniczyç powstawanie pró ni przy odpowietrzaniu otworzyç króci...

Reviews: