HPRV (60/68)
Pressure Limiter Screens
W
Warning
Pumps with only HPRV valves no longer contain pressure limiter (PL) screens and retainer. To convert the
pumps to use pressure limiter valves, please contact your Danfoss Service Partner. Pumps that have PL
valves without PL screens and retainers are at high risk of contamination and product malfunction.
H1P Base Models with pressure settings option B include PL screens and retainers.
HPRV Repair (060/068)
The high pressure relief and charge check valve assemblies may be removed for cleaning and
replacement of the O-rings. These valves are factory set and are not field adjustable. Refer to the pump
model code for the factory setting when ordering replacements.
QL301
P109251
L101
L060
L068
L201
port C
port D
port A
port B
L060
L068
L100
L200
QL401
L022
L024
L300, L301,
L400, L401
L022
QL300
QL400
L022
L024
For ports
C and D
For ports
A and B
Item
Description
Wrench size
Torque
L300, L301, L400, L401
Pressure limiter plug assembly
14 mm
30 N•m [22 lbf•ft]
QL300, QL301, QL400, QL401
Pressure limiter valve assembly
17 mm
30 N•m [22 lbf•ft]
L100, L101, L200, L201
High Pressure Relief Valve
22 mm
70 N•m [51.6 lbf•ft]