Servo Adjustment for Tandem Pumps
Servo and system pressure gauge port locations (045/053)
MD
MA
M4
M5
P109257
D
A
C
B
M4
M5
E300
E350
Control Cutoff (CCO)
1
MB
MC
X7
AM3
MC
MB
AM3
Legend:
Ports per ISO 11926–1
A, B, C, D
System port: 1
5
/
16
–12
MA, MB, MC, MD
System gauge port:
9
/
16
–18
M3, AM3
Charge port:
9
/
16
–18
M4, M5
Servo gauge port:
7
/
16
–20
X7
Brake gauge port:
9
/
16
–18
Service Manual
H1T 045/053, 060/068 Axial Piston Tandem Pumps
Adjustments
©
Danfoss | September 2020
AX152886481761en-000405 | 53