15. Press the seal until it is flush 0.12mm [0.005 in] or -0.72 mm [0.0028 in] of the inside lip of the
carrier:
see illustration.
Positioning seal in seal carrier
Seal
Press flush to this surface
+0.12 mm [ 0.005 in] / -0.72 mm [ 0.028 in]
16. Cover the shaft with a protective sleeve while installing the seal carrier.
17. Hand press the seal carrier into the housing.
18. Ensure the seal carrier clears the spiral ring groove in the housing.
19. Remove the protective sleeve.
20. Wind the spiral ring into the housing.
21. Ensure the inside diameter of the spiral ring is greater than 68 mm [2.677 in] after installation.
Service Manual
H1P 045/053/060/068 Axial Piston Single Pumps
Minor Repair
©
Danfoss | June 2020
AX152886481964en-000405 | 59