C
Caution
Do not damage the housing in the plug sealing area.
5. Use a 5 mm internal hex to remove two screws (D674) and remove shield (D672).
6. Use a 5 mm internal hex to remove six screws (D250) and remove control from pump.
7. Remove and discard gasket (D150).
Alignment pins are pressed into control. Do not remove them.
8. If necessary, remove orifices (F00A, F00B) using a 3 mm internal hex.
Tag and number the orifices for reinstallation.
9. If it is necessary to remove the screens, drill out screen retention ring (D098).
Drill Out Retention Ring
Screen
Retention
Ring
P108 022E
Note screen orientation for reassembly.
10. Remove and discard screen (D084).
Service Manual
H1P 045/053/060/068 Axial Piston Single Pumps
Minor Repair
56 |
©
Danfoss | June 2020
AX152886481964en-000405