Automotive Control Repair
Drain pump completely before removing control.
Possible erratic pump operation.
Do not allow metal fragments to fall into control housing. Do not fail to install screen.
D250
5 mm
(6X)
D150
F00A
3 mm F00B
P107 990E
D610 (2X)
Security
wax seal (2X)
D640
D084
D098
13.3 Nm
[9.8 lbf•ft]
2.5 Nm
[1.8 lbf•ft]
D674
D672
1. Disconnect and remove wiring (D640).
2. Fabricate a special tool to remove two plastic plugs (D610).
See drawing below for tool dimensions.
Special
tool
Plug
P108 021E
Ø 1.7 mm (x3)
Ø 9.22 mm
45 deg.
Ø 14 mm
3. Push down on plug and turn 45 degrees counterclockwise.
4. Discard plugs.
Wax seals will be destroyed when the plugs are removed.
Service Manual
H1P 045/053/060/068 Axial Piston Single Pumps
Minor Repair
©
Danfoss | June 2020
AX152886481964en-000405 | 55