Remove servo cylinders
E250
E600
E300
E101 410E
E350
10 mm
Servo Piston Removal
Tilt swashplate up to disengage servo arm from piston. Remove the servo piston assembly (E100).
Remove servo piston
P108 489E
E100
Swashplate and Swashplate Bearing Removal
1. Lift the swashplate (D070) out by grasping the swashplate pin. Swashplate bearings will remain on
the swashplate.
2. Remove bearings. Note bearing orientation.
Repair Instructions
H1 45/53/60/68 Closed Circuit Axial Piston Pumps
Disassembly
520L0957 • Rev CB • September 2014
17