Inspect servo assembly
P101 337E
Control
Inspect sealing surfaces of control. If you find nicks or scratches that may allow fluid leakage, replace
control. Inspect feedback spring and linkage. Control is available as a complete unit only. If you suspect
control operation problems, replace control with a new unit and test pump. If necessary, you may remove
and clean the control orifices. Use a 3 mm internal hex. wrench Torque to 2.5 N•m [1.8 lbf•ft]. Remove and
replace the screen if it is clogged.
If you suspect a coil malfunction, remove the coil by removing the plastic nut with a 26 mm 12 point
socket. Install a new coil. Torque nut to 5 N•m [3.7 lbf•ft].
Inspect control
E101 475E
Screen
Repair Instructions
H1 45/53/60/68 Closed Circuit Axial Piston Pumps
Inspection
28
520L0957 • Rev CB • September 2014