P106 230E
1
2
3
4
5
6
Valveplate orientation
CW
CCW
Clockwise valveplate
Counterclockwise v
alveplate
Notch used for NFPE or AC controls
Notch used for EDC or FNR controls
P108 060E
Charge Pump Installation
Charge pump components are available as a complete kit only. Kit includes (S300), (S250), (S100), (S150),
and (S200).
1. Install new seal (S300) to valve plate (S250). Lubricate valve plate (S250) and install in same
orientation as when it was removed.
2. Lubricate and install outer ring (S150) and charge pump gearset (S100). Lubricate and install coupling
(K200).
3. Lubricate and install pressure-balance plate (S200) in same orientation as when it was removed.
Install new outer seal (S300).
4. Lubricate and install thrust washer (K500) in same orientation as when it was removed.
Bump on thrust washer fits into hole in cover.
Repair Instructions
H1 45/53/60/68 Closed Circuit Axial Piston Pumps
Assembly
38