Special Tool
Special
tool
Plug
P108 021E
Ø 1.7 mm (x3)
Ø 9.22 mm
45 deg.
Ø 14 mm
Inspection
Inspect machined surfaces on control and pump housing. Inspect plastic PC board housing and its
sealing areas. If any damage is found, replace damaged components.
Controls are available as a complete unit. Do not disassemble the control.
Assembly
1. If previously removed, install new screen (D084) in original orientation. Press in new retention ring
(D098).
Be sure screen will not move axially in bore after retention ring is installed.
W
Warning
Failure to install screen will result in erratic pump operation.
Proper Screen Orientation
P106 618E
D084
D084
Incorrect screen
orientation
Correct screen
orientation
D094
2. If previously removed, use a 3 mm internal hex to install orifices (F00A, F00B) in original orientation.
Torque to 2.5 N•m [1.8 lbf•ft][.
3. Install new gasket (D150) to bottom of control.
If pump has been rebuilt or a new control is being installed, control software must be recalibrated.
Refer to H1-Automotive Control User Manual 70012797 for recalibration instructions.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Minor Repair
50 |
©
Danfoss | May 2018
520L0848 | AX00000087en-US0308