Minimum servo pressure at corner power holds the pump on full stroke at max speed and max
pressure.
Maximum servo pressure is the highest pressure typically given by the charge pressure setting.
Charge pressure
An internal charge relief valve regulates charge pressure. Charge pressure supplies the control with
pressure to operate the swashplate and to maintain a minimum pressure in the low side of the
transmission loop.
The charge pressure setting listed in the order code is the set pressure of the charge relief valve with the
pump in neutral, operating at 1800 min
-1
[rpm], and with a fluid viscosity of 32 mm²/s [150 SUS].
Pumps configured with no charge pump (external charge supply) are set with a charge flow of 30 l/min
[7.93 US gal/min] and a fluid viscosity of 32 mm²/s [150 SUS].
The charge pressure setting is referenced to case pressure. Charge pressure is the differential pressure
above case pressure.
Minimum charge pressure is the lowest pressure allowed to maintain a safe working condition in the
low side of the loop. Minimum control pressure requirements are a function of speed, pressure, and
swashplate angle, and may be higher than the minimum charge pressure shown in the Operating
parameters tables.
Maximum charge pressure is the highest charge pressure allowed by the charge relief adjustment, and
which provides normal component life. Elevated charge pressure can be used as a secondary means to
reduce the swashplate response time.
Charge pump inlet pressure
At normal operating temperature charge inlet pressure must not fall below
rated charge inlet pressure
(vacuum)
. Minimum charge pump inlet pressure is only allowed at cold start conditions. In some
applications it is recommended to warm up the fluid (e.g. in the tank) before starting the engine and then
run the engine at limited speed. Maximum charge pump inlet pressure may be applied continuously.
Case pressure
Under normal operating conditions, the rated case pressure must not be exceeded. During cold start case
pressure must be kept below maximum intermittent case pressure. Size drain plumbing accordingly.
Auxiliary Pad Mounted Pumps. The auxiliary pad cavity of H1 pumps configured without integral charge
pumps is referenced to case pressure. Units with integral charge pumps have auxiliary mounting pad
cavities referenced to charge inlet (vacuum).
C
Caution
Possible component damage or leakage.
Operation with case pressure in excess of stated limits may damage seals, gaskets, and/or housings,
causing external leakage. Performance may also be affected since charge and system pressure are
additive to case pressure.
External shaft seal pressure
In certain applications, the input shaft seal may be exposed to external pressures. The shaft seal is
designed to withstand an external pressure up to 0.4 bar [5.8 psi] above the case pressure. The case
pressure limits must also be followed to ensure the shaft seal is not damaged.
Service Manual
H1 Pumps 069/078, 089/100, 115/130, 147/165, 210/250
Operating parameters
©
Danfoss | May 2018
520L0848 | AX00000087en-US0308 | 19