Danfoss FT1312 Hose Proof Test Stand Operators Manual
5 | Danfoss FT1312 Hose Proof Test Stand Operators Manual | 2023.06.
AQ452153740268en-010101
Maintenance
Troubleshooting
Normal maintenance requires periodic refilling of the lubricator on the water pump and cleaning the see-through lid with clean, soapy water. Do
not use petroleum or chemical solvents on the see-through lid. Use only mild detergent.
PROBLEM
SOLUTION
Test pressure not attainable during operation
1. Check all connections of tooling and and hose assemblies for leaks.
2. Check high pressure dump valve is closed.
3.
Bleed air from test sample.
Power unit not functioning when air regulator adjusted.
1.
Supply air not connected or air shut-off valve not open.