5.2 Derating
Limits
To ensure that the inverters can produce the rated power,
measurement inaccuracies are taken into account when
enforcing the derating limits stated in
Table 5.5
.
(Limit = rated value + tolerance).
FLX series
5
6
7
8
9
10
12.5
15
17
Grid current, per phase
7.5 A
9.0 A
10.6 A
12.1 A
13.6 A
15.1 A
18.8 A
22.6 A
25.6 A
Grid power, total
5150 W
6180 W
7210 W
8240 W
9270 W
10300 W
12875 W
15450 W
17510 W
Table 5.5 Derating Limits
5.3 Conformity
FLX series
International
Standards
5
6
7
8
9
10
12.5
15
17
Directive LVD
2006/95/EC
Directive EMC
2004/108/EC
Safety
IEC 62109-1/IEC 62109-2
Integrated PV load switch
VDE 0100-712
Functional Safety
IEC 62109-2
EMC immunity
EN 61000-6-1
EN 61000-6-2
EMC emission
EN 61000-6-3
EN 61000-6-4
Utility interference
EN 61000-3-2/-3
EN 61000-3-11/-12
CE
Yes
Utility characteristics
IEC 61727
EN 50160
S0 Energy Meter (option)
EN62053-31 Annex D
Table 5.6 International Standards Compliance
Technical Data
38
L00410568-02_02 / Rev. date: 2013-12-10
5