Nomen-
clature
Parameter
FLX series
5
6
7
8
9
Max. short-circuit
current DC (at STC)
13.5 A per PV input
Min. on grid power
20 W
Efficiency
Max. efficiency
-
97.8%
-
97.9%
-
Euro efficiency, V at
dc,r
-
96.5%
-
97.0%
-
Other
Dimensions (H, W,
D), inverter / incl.
packaging
667 x 500 x 233 mm / 774 x 570 x 356 mm
Mounting
recommendation
Mounting plate
Weight, inverter /
incl. packaging
38 kg / 44 kg
Acoustic noise level
4
-
MPP trackers
2
Operation
temperature range
-25..60 °C
Nom. temperature
range
-25..45 °C
Storage temperature
-25..60 °C
Overload operation
Change of operating point
Overvoltage
categories
Grid: OVC III
PV: OVC II
Table 5.1 Specifications
1)
At rated grid voltage (V
ac,r
), Cos(phi)=1.
2)
To utilise the full range, asymmetrical layouts must be considered
including start-up voltage for at least 1 string. Achieving nominal
power will depend on configuration.
3)
At symmetric input configuration.
4)
SPL (Sound Pressure Level) at 1 m under normal operating
conditions. Measured at 25 °C.
Nomen-
clature
Parameter
FLX series
10
12.5
15
17
AC
|S|
Rated apparent
power
10 kVA
12.5 kVA
15 kVA
17 kVA
P
ac,r
Rated active power
1)
10 kW
12.5 kW
15 kW
17k W
Active power at
cos(phi)=0.95
9.5 kW
11.9 kW
14.3 kW
16.2 kW
Active power at
cos(phi)=0.90
9.0 kW
11.3 kW
13.5 kW
15.3 kW
Reactive power
range
0 - 6.0 kVAr
0-7.5 kVAr
0-9.0 kVAr
0-10.2 kVAr
V
ac,r
Nominal AC voltage
(AC voltage range)
3P+N+PE - 230/400 V (+/- 20 %)
Rated current AC
3 x 14.5 A
3 x 18.2 A
3 x 21.7 A
3 x 24.7 A
Technical Data
L00410568-02_02 / Rev. date: 2013-12-10
35
5
5