Produced by Danfoss Floor Heating Hydronics 05.2011
17
VI.CU.C2.2D
Produced by Danfoss Floor Heating Hydronics 05.2011
Instruction FH-CWP Thermostat
9. Frost protection
Using the Frost Protection Mode instead of turning
the thermostat OFF completely may protect against
damages due to low temperatures. The room tem-
perature will be maintained around 5 °C.
Turn OFF the thermostat by pressing Fig. 1
.
• Press
M
Fig.1
for 3 seconds and release.
• Select 01 (00= disabled).
If the temperature is lower than 5 °C the heating
will be turned ON and will be shown in the
display.
If the temperature is higher than 7 °C the heating
is turned OFF.
Factory setting is 00.
10. Error messages
E1 will be displayed when room sensor failure.
E2 will be displayed when floor sensor failure.
E2 will be read when pressing
M
Fig. 1
to check
floor temperature.
Any case, all relay output would be turned off.
Summary of Contents for FH-CWP
Page 1: ...Instruction FH CWP Thermostat ...
Page 2: ......
Page 38: ...38 VI CU C2 2D Изготовлено 05 2011 компанией Danfoss FHH Инструкция для термостата FH CWP ...
Page 56: ...56 VI CU C2 2D FH CWP Thermostat Gebrauchsanweisung Hergestellt von Danfoss FHH 05 2011 ...
Page 89: ...89 VI CU C2 2D FH CWP温控器使用说明 丹佛斯水地暖产品 05 2011 ...
Page 96: ...www heating danfoss com ...