background image

INFRARED THERMOMETER

INFRARED THERMOMETER

Intelligent Infrared Thermometer with Emissivity 

Smart and Color Identification Signal

INFRARED THERMOMETER

INFRARED THERMOMETER

RoHS

COMPLIANT

H brid

y

H brid

y

3

ST-643

Summary of Contents for Hybrid ST-643

Page 1: ...RED THERMOMETER INFRARED THERMOMETER Intelligent Infrared Thermometer with Emissivity Smart and Color Identification Signal INFRARED THERMOMETER INFRARED THERMOMETER RoHS COMPLIANT H brid y H brid y 3 ST 643 ...

Page 2: ......

Page 3: ...Instruction Manual Version 01 07 NOV Hybrid Hybrid Infrared Thermometer RoHS COMPLIANT ...

Page 4: ......

Page 5: ...1 Electronic trigger lock function ...

Page 6: ...2 ...

Page 7: ...nt for measurement control and laboratory use IEC61000 4 2 Electrostatic discharge immunity test IEC61000 4 3 Radiated radio frequency Electromagnetic field immunity test IEC61000 4 8 Power frequency magnetic field immunity test ...

Page 8: ...may not be disposed of with the trash It promotes the re use recycling and other forms of recovery of used materials and components and to improve the environmental performance of all operators manufacturers traders treatment facilities involved in the life cycle of products Dispose of the product appropriately in accordance with the regulations in force in your country 4 ...

Page 9: ... F 9V Battery Instruction manual Carrying case Repeatability Resolution Response Time Emissivity Switchable LCD Backlight Auto Power Off Laser Sight Switchable Dimensions Weight E Smart Operation Temp Thermocouple K Type CIS 1 C 2 F 0 1 C 0 1 F 500 ms Automatically after approx 6 sec 180x130x40mm 7 09 x5 12 x1 57 0 50 C 32 122 F 10 95 RH YES YES YES YES Adjustable 0 1 1 0 YES Thermocouple Range 20...

Page 10: ...4 Operations of Instrument 4 1 Quick Start 4 2 Unit Diagram 6 ...

Page 11: ...Primary Display Max Min Avg Secondary Display Lock Key Up Button Function Key Low Battery Laser Buzzer On Off Data Log Thermocouple Emissivity High Low Alarm Memory Key Down Button 1 2 3 4 5 6 8 9 10 11 12 7 13 14 15 8 9 10 11 12 13 14 15 1 2 3 4 5 6 7 ...

Page 12: ...EMS 8 ...

Page 13: ...arm temperature Memory Activate the record function by push the M button To delete all the records press up or down button to DATA 0 and press M button Lock Push the button to continuously measure and display the temperature without pull the measuring trigger Function The above functions can be activated always in any step of operations mode in flow chart Scan Hold In SCAN mode the LCD displays bo...

Page 14: ...10 ...

Page 15: ...s of the unit The FOV is the ratio of the distance from the target to the target diameter The smaller the target the closer you should be to it When the target diameter is small it is important to bring the thermometer closer to the target to insure that only the target is measured excluding the surroundings 11 5 Techniques of Infrared Thermometer 5 1 ...

Page 16: ...n object at a given temperature to the energy emitted by a perfect radiator at the same temperature All values of emissivity fall between 0 0 and 1 0 6 Maintenance Cleaning the lens Blow off loose particles using clean compressed air Gently brush remaining debris way with a camel s hair brush Carefully wipe the surface with a moist cotton swab The wab may be moistened with water NOTE DO NOT use so...

Page 17: ...ass hard rolled polished w lines 21 70 0 04 Iron galvanized bright 0 13 Iron plate completely 20 68 0 69 Rolled sheet steel 21 71 0 66 Oxidized iron 100 212 0 74 Wrought iron 21 70 0 94 Molten iron 1299 1399 3270 2550 0 29 Copper polished 21 117 70 242 0 02 Copper scraped shiny not mirrored 22 72 0 07 Copper Plate heavily oxidized 25 77 0 78 Enamel white fused on iron 19 66 0 9 Formica 27 81 0 94 ...

Page 18: ...PA05 000064X 01 ...

Page 19: ...ST 643 Version 01 07 NOV 3F No 122 Sec 1 Sanmin Road Ban Ciao Taipei 220 Taiwan R O C TEL 886 2 2956 8198 FAX 886 2 2956 7662 http www sentrytek com tw PA05 0000643 01 ...

Reviews: