Pa
r. No. #
Pa
rame
ter de
scri
pt
io
n
Def
ault value
4-
se
t-
up
FC 30
2
on
ly
Cha
nge duri
ng op
-
erat
ion
Co
nver-
sion index
Typ
e
26-0*
Analog I/O Mode
26-
00
Termi
nal
X4
2/
1 Mo
de
[1
] Vol
tag
e
All se
t-
up
s
TRU
E
-
Ui
nt
8
26-
01
Termi
nal
X4
2/
3 Mo
de
[1
] Vol
tag
e
All se
t-
up
s
TRU
E
-
Ui
nt8
26-
02
Termi
nal
X4
2/
5 Mo
de
[1
] Vol
tag
e
All se
t-
up
s
TRU
E
-
Ui
nt8
26-1
*
An
alog In
put
X42/
1
26-
10
Termi
nal
X42/
1
Lo
w Vo
ltag
e
0.0
7 V
Al
l s
et
-up
s
TR
U
E
-2
Int
16
26-
11
Termi
nal
X42/
1 Hi
gh
Vo
ltag
e
10.
00 V
All se
t-
up
s
TRU
E
-2
In
t1
6
26-
14
Term.
X42/
1
Lo
w R
ef.
/Fe
ed
b.
Value
0.
000
N/A
Al
l set-
up
s
TR
U
E
-3
In
t32
26-
15
Te
rm. X
42
/1
H
ig
h
Ref
./
Feed
b.
Va
lu
e
100
.00
0 N/A
All se
t-
up
s
TRU
E
-3
In
t3
2
26-
16
Term.
X42/
1 Fi
lter Ti
me
Co
nstant
0.0
01 s
Al
l set-
up
s
TR
U
E
-3
U
in
t1
6
26-
17
Term.
X42/
1 Live
Zero
[1] Enabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt8
26-2
*
An
alog In
put
X42/
3
26-
20
Termi
nal
X42/
3
Lo
w Vo
ltag
e
0.0
7 V
All se
t-
up
s
TRU
E
-2
In
t1
6
26-
21
Termi
nal
X42/
3 Hi
gh
Vo
ltag
e
10.
00
V
Al
l set-
up
s
TR
U
E
-2
In
t16
26-
24
Term.
X42/
3 Lo
w
R
ef.
/Fe
ed
b.
Value
0.
000 N/A
All se
t-
up
s
TRU
E
-3
In
t3
2
26-
25
Term.
X42/
3 Hi
gh
R
ef
./
Fe
ed
b.
Val
ue
100
.00
0 N/A
Al
l set-
up
s
TR
U
E
-3
In
t32
26-
26
Term.
X42/
3 Fi
lter Ti
me
Co
nstant
0.0
01 s
All se
t-
up
s
TRU
E
-3
Ui
nt1
6
26-
27
Term.
X42/
3 Live
Zero
[1] Enabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt8
26-3
*
An
alog In
put
X42/
5
26-
30
Termi
nal
X42/
5
Lo
w Vo
ltag
e
0.0
7 V
Al
l s
et
-up
s
TR
U
E
-2
Int
16
26-
31
Termi
nal
X42/
5 Hi
gh
Vo
ltag
e
10.
00 V
All se
t-
up
s
TRU
E
-2
In
t1
6
26-
34
Term.
X42/
5
Lo
w R
ef.
/Fe
ed
b.
Value
0.
000
N/A
Al
l set-
up
s
TR
U
E
-3
In
t32
26-
35
Te
rm. X
42
/5
H
ig
h
Ref
./
Feed
b.
Va
lu
e
100
.00
0 N/A
All se
t-
up
s
TRU
E
-3
In
t3
2
26-
36
Term.
X42/
5 Fi
lter Ti
me
Co
nstant
0.0
01 s
Al
l set-
up
s
TR
U
E
-3
U
in
t1
6
26-
37
Term.
X42/
5 Live
Zero
[1] Enabl
ed
All se
t-
up
s
TRU
E
-
Ui
nt8
26-4
*
An
alog
Ou
t X42/
7
26-
40
Termi
nal
X42/
7 Output
[0
] N
o
ope
rat
io
n
All se
t-
up
s
TRU
E
-
Ui
nt8
26-
41
Termi
nal
X42/
7 Mi
n.
Scale
0.
00 %
Al
l set-
up
s
TR
U
E
-2
In
t16
26-
42
Termi
nal
X42/
7 Max.
Scal
e
100.
00 %
All se
t-
up
s
TRU
E
-2
In
t1
6
26-
43
Termi
nal
X42/
7 Bus
Co
nt
ro
l
0.
00 %
Al
l set-
up
s
TR
U
E
-2
N
2
26-
44
Termi
nal
X42/
7 Ti
me
out P
rese
t
0.
00 %
1 se
t-up
TRU
E
-2
Ui
nt1
6
26-5
*
An
alog
Ou
t X42/
9
26-
50
Termi
nal
X42/
9 Output
[0
] N
o
ope
rat
io
n
All se
t-
up
s
TRU
E
-
Ui
nt8
26-
51
Termi
nal
X42/
9 Mi
n.
Scale
0.
00 %
Al
l set-
up
s
TR
U
E
-2
In
t16
26-
52
Termi
nal
X42/
9 Max.
Scal
e
100.
00 %
All se
t-
up
s
TRU
E
-2
In
t1
6
26-
53
Termi
nal
X42/
9 Bus
Co
nt
ro
l
0.
00 %
Al
l set-
up
s
TR
U
E
-2
N
2
26-
54
Termi
nal
X42/
9 Ti
me
out P
rese
t
0.
00 %
1 se
t-up
TRU
E
-2
Ui
nt1
6
26-6
*
An
alog
Ou
t X42/
11
26-
60
Termi
nal
X42/
11 Outp
ut
[0
] N
o
ope
rat
io
n
All se
t-
up
s
TRU
E
-
Ui
nt8
26-
61
Termi
nal
X42/
11 Mi
n.
Scale
0.
00 %
Al
l set-
up
s
TR
U
E
-2
In
t16
26-
62
Termi
nal
X42/
11 Max.
Scal
e
100.
00 %
All se
t-
up
s
TRU
E
-2
In
t1
6
26-
63
Termi
nal
X42/
11 Bus
Co
nt
ro
l
0.
00 %
Al
l set-
up
s
TR
U
E
-2
N
2
26-
64
Termi
nal
X42/
11 Time
ou
t
Pr
es
et
0.
00 %
1 se
t-up
TRU
E
-2
Ui
nt1
6
5.1.24
.
26-**
A
n
alog
I /
O Option MCB
109
5. Parameter Lists
VLT
®
HVAC Drive Programming Guide
272
MG.11.C5.02 - VLT
®
is a registered Danfoss trademark
5