background image

RI8JC353

 

    10-2009

084R9792

INSTRUCTIONS

EKC 368  

084R9792

Identification

Sair, Sdef:
Pt 1000 ohm /0°C 
(AKS 11)

Dimensions

Principle

IP 20

084B7079

Summary of Contents for EKC 368

Page 1: ...RI8JC353 10 2009 084R9792 INSTRUCTIONS EKC 368 084R9792 Identification Sair Sdef Pt 1000 ohm 0 C AKS 11 Dimensions Principle IP 20 084B7079 ...

Page 2: ...r English Dansk Principle Necessary connections Terminals 25 26 Supply voltage 24 V a c 18 19 Pt 1000 sensor at evaporator outlet 21 24 Supply to step motor 1 2 Switch function for start stop of regulation If a switch is not con nected terminals 1 and 2 must be shortcircuited 5 6 Battery the voltage will open the KVS valve if the controller loses its supply voltage Application dependent connection...

Page 3: ...larme et si le régulateur est hors tension 8 9 Contact de relais pour marche arrêt du dégivrage 8 10 Relais marche arrêt du ventilateur 8 11 Contact de relais pour marche arrêt du refroidissement 16 17 Signal de courant d une autre régulation Ext Ref Si le signal de tension reçu provient d un automate PLC ou simi laire il faut que le module de transfert éventuel soit à isolation galvanique 18 20 S...

Page 4: ...mperaturalarm A2 Lavtemperaturalarm A43 Kontrollér forsyningsspændingen til stepmotoren A44 Batterialarm ingen eller for lav spænding Funktion Para meter Min Max Fab indst Normalbillede Viser temperaturen ved rumføleren C Tryk kortvarigt på den nederste knap for at se temperaturen ved afrimningsføleren C Reference Indstil den ønskede rumtemperatur 70 C 160 C 10 Temperaturenhed r05 C F C Eksternt b...

Page 5: ...g input signal is outside the range A1 Alarm message High temperature alarm A2 Low temperature alarm A43 Check supply voltage for the step engine A44 Battery alarm no voltage or too low voltage Function Para meter Min Max Fac set ting Normal display Shows the temperature at the room sensor C Give the lower button a brief push to see the temperature at the defrost sensor C Reference Set the require...

Page 6: ...naloges Eingangssignal außerhalb des Bereichs A1 Alarmmitteilung Hoch Temperaturalarm A2 Tief Temperaturalarm A43 Kontrolle der Versorgungsspannung zum Stepmotor A44 Batteriealarm keine oder zu niedrige Spannung Funktion Para meter Min Max Werks einstel lung Normalbild Anzeige der Temperature am Raumfühler C Kurzzeitig die unterste Taste betätigen um die Temperatur beim Abtaufühler anzuzeigen C So...

Page 7: ...ur A44 Alarme batterie tension trop basse ou défaillante Francais Function Para meter Min Max Reg usine Image normale Indique la température de la sonde d ambiance C Appuyer brièvement sur le bouton inférieur pour afficher la température de la sonde de dégivrage C Référence Régler la température ambiante désirée 70 C 160 C 10 Unités de température r05 C F C Supplément externe de la référence r06 5...

Page 8: ...rvice Lectura de la temperatura del sensor Sair u01 C Lectura referencia de regulación u02 C Lectura de la señal de corriente externa u07 V Lectura de la temperatura del sensor Sdef u09 C Lectura del estado de entrada DI u10 on off Lectura de la duración del desescarche u11 m Grado de apertura de la válvula u23 Este ajuste será posible solo si se ha instalado una tarjeta de comunicación en el cont...

Reviews: