Danfoss ECtemp Next Plus

Installation Guide

4

Ambient temperature

-10°C to +60°C

Frost protection temperature

5°C to +9°C (default 5°C)

Temperature range

Room temperature: 5-35°C.

Floor temperature: Max. 35°C 

is default.

Sensor failure monitoring

The thermostat has a built-in 

monitoring circuit, which will 

switch off the heating if the 

sensor is disconnected or short-

circuited

Cable specification max.

1x4 mm

2

 or 2x2,5 mm

2

Ball pressure test temperature

75°C

Pollution degree

2 (domestic use)

Controller type

1C

Software class

A

Storage temperature

-20°C to +65°C

IP class

30

Protection class

Class II - 

Dimensions

 86 x 86 x 16/40.5 mm  

(in-wall depth: 24.5 mm)   

Weight

103 g

Electrical safety and Electro-Magnetic Compatibility for 

this product is covered by the compliance with the EN/IEC 

Summary of Contents for ECtemp Next Plus

Page 1: ...Danfoss ECtemp Next Plus Electronic Intelligent Timer Thermostat Installation Guide electricheating danfoss com...

Page 2: ...Programmable Timer 13 4 4 Temperature Setting 15 4 5 Timer Setting 16 4 6 Safety Lock 17 4 7 Away Mode 17 4 8 Present Floor Temperature 17 4 9 Change to Room control only 18 4 10 Extending Maximum fl...

Page 3: ...ect heating of the entire room and for comfort heating of the floor More information on this product can also be found at electricheating danfoss com 1 1 Technical Specifications Operation voltage 85...

Page 4: ...which will switch off the heating if the sensor is disconnected or short circuited Cable specification max 1x4 mm2 or 2x2 5 mm2 Ball pressure test temperature 75 C Pollution degree 2 domestic use Con...

Page 5: ...heating element in connection with a wooden floor or similar material always use a floor sensor and never set the maximum floor temperature to more than 35 C Please also note the following The instal...

Page 6: ...s place the thermostat according to local regulation on IP classes and use floor sensor only Do not place the thermostat on the inner side of an exterior wall Always install the thermostat at least 50...

Page 7: ...nduit should be flush with the floor surface countersink the conduit if necessary Route the conduit to the connection box The bending radius of the conduit must be min 50mm Connect the thermostat acco...

Page 8: ...Symbols Function description Room temperature Away mode Floor temperature Child safety lock Temperature indication Power ON OFF SET Set temperature Timer and program operation Floor heating Active M...

Page 9: ...ed when the unit is activated for the first time Press M button for 6 seconds to enter the parameter setting mode The upper digits indicate the parameter number Press M for parameter selection Press o...

Page 10: ...Frost protection setpoint 5 9 C 5 C P06 Timer display option 01 24h 02 12h 01 P07 Room temp display option at shutdown 01 No display surrent temp 02 Display current temp 01 It will be possible to use...

Page 11: ...e or to select the temperature 4 Press to accept the setting P1 Event 2 4 Repeat the Event 1 procedure for programming Event 2 4 P2 Sa Su are now shown in the display P2 Event 1 1 Use or to select the...

Page 12: ...3 Event 4 Start time Temp Start time Temp Start time Temp Start time Temp Mon Fri 6 30 20 C 27 C 8 30 15 C 25 C 16 30 20 C 27 C 22 30 25 C 25 C Sat Sun 7 30 20 C 27 C 9 30 20 C 27 C 16 30 21 C 28 C 2...

Page 13: ...sed to control a floor heating element in connection with a wooden floor or similar material always use a floor sensor and never set the maximum floor temperature to more than 35 C Thermal resistance...

Page 14: ...t day Finish timer setting by pressing any other button or wait for automatic exit after 6 sec without operation 4 6 Safety Lock Press M and simultaneous to enable Safety lock To release safety lock p...

Page 15: ...mer buttons simultaneously for approx 10 seconds Select Function P08 Only Room temperature control Select Setting 01 Enable Switch Power ON Press M button for approx 6 seconds Select Parameter Setting...

Page 16: ...y and 4 10 Extending Maximum Floor temperature limitations to 45 C No Function Setting Factory default Danfoss ECtemp Next Plus P01 Room Sensor Calibration Offset 10 C to 10 C 0 C P02 Floor Sensor Cal...

Page 17: ...ting range extension for P06 P07 P08 01 Max 35 C 02 Max 45 C 01 P08 Only room temperature control 01 Enable 02 Disable 02 5 Error Codes E1 Room sensor failure E2 Floor sensor failure EE EEPROM failure...

Page 18: ...Danfoss ECtemp Next Plus Installation Guide 18 7 Disposal Instruction...

Page 19: ...Danfoss ECtemp Next Plus 19 Installation Guide...

Page 20: ...Danfoss ECtemp Next Plus Installation Guide 20...

Page 21: ...Danfoss ECtemp Next Plus 21 Installation Guide...

Page 22: ...Danfoss ECtemp Next Plus Installation Guide 22...

Page 23: ...ible errors in catalogues brochures and other printed material Danfoss reserves the right to alter its products without notice This also applies to products already on order provided that such alterat...