Danfoss ECtemp Next Plus
Installation Guide
10
The digits indicate the set value as follows:
No� Parameter settings
Settings range
Default
P01 Working mode
01: Manual
02: Advanced Program-
mable Timer
02
P02 Temperature control
mode
01: Room and floor temp;
02: Only floor temp.;
03: Only room temp.*
01
P03 Maximum floor
temperature
20-30˚C (only for 01 in
P02)**
35˚C
P04 Frost protection
01: Enable; 02: Disable
01
P05 Frost protection
setpoint
5-9˚C
5˚C
P06 Timer display option
01: 24h; 02 12h
01
P07 Room temp. display
option at shutdown
01: No display surrent
temp.;
02: Display current temp.
01
* It will be possible to use only a room sensor. However, this option is not recom-
mendable due to an increased risk of overheating the floor.
See 4.9 Change to
Room control only
** P03 appears on relevant temperature control mode.
See 4.10 Extending
Maximum floor temperature limitations to 45°C
4�3
Advanced Programmable Timer
The Advanced Programmable Timer mode enables the set-
ting of a timer-controlled program for automatic comfort