Installation Guide
• Place the floor sensor in a conduit in an appropriate place
where it is not exposed to sunlight or draft from door
openings.
• Equally distant and >2cm from two heating cables.
• The conduit should be flush with the floor surface -
countersink the conduit if necessary.
• Route the conduit to the connection box.
• The bending radius of the conduit must be min 50mm.
Connect the thermostat according to the connection
diagram.
The screen of the heating cable must be connected to
the earth conductor of the power supply cable by using a
separate connector.
Note:
Always install the floor sensor in a conduit in the
floor.