Danfoss ECtemp Next Plus
13
Installation Guide
It would also be possible to use only one temperature
sensor. However, this option is not recommendable as this
cause an increased risk of overheating of the floor.
Extending maximum floor temperature and Setting into
room only mode – See point 4.9 and 4.10.
IMPORTANT:
When the thermostat is used to control a
floor heating element in connection with a wooden floor or
similar material, always use a floor sensor and never set the
maximum floor temperature to more than 35 ° C.
Thermal
resistance
[m
2
K/W]
Examples of
Flooring
Details
Approximate
setting for
25˚C floor
temperature
0.05
8 mm HDF
based lami-
nate
>800 kg/m
3
28˚C
0.10
14 mm beech
parquet
650 - 800
kg/m
3
31˚C
0.13
22 mm solid
oak plank
>800 kg/m
3
32˚C
< 0.17
Max. carpet
thickness suit-
able for floor
heating
acc. to EN
1307
34˚C
0.18
22 mm solid
for planks
450 - 650
kg/m
3
35˚C