Danfoss ECdry Touch Kit
Maximum heated surface per ECdry Touch Kit (10 A limit per system)
Product
Max heated surface
ECdry 55
42 m²
ECdry 100
23 m²
For ECdry 55 (Mains voltage 230 Volt and 50 Hz)
Floor area
Heated surface
Total power output
Ampere
1 m²
0,4 m²
22 Watt
0,10 A
2 m²
1,4 m²
77 Watt
0,33 A
3 m²
2,4 m²
132 Watt
0,57 A
4 m²
3,4 m²
187 Watt
0,81 A
5 m²
4,4 m²
242 Watt
1,05 A
For ECdry 100
Floor area
Heated surface
Total power output
Ampere
1 m²
0,4 m²
40 Watt
0,17 A
2 m²
1,4 m²
140 Watt
0,61 A
3 m²
2,4 m²
240 Watt
1,04 A
4 m²
3,4 m²
340 Watt
1,48 A
5 m²
4,4 m²
440 Watt
1,91 A
1�1
Calculating current limitations
The ECdry floor heating system should be
connected in accordance with national stan-
dards and wiring rules.
Maximum current per ECdry system is 10
Ampere.
In the following tables you will find maxi-
mum heated surface per ECdry Touch Kit
and an overview of the total power output
of the systems.