AN324050550815en-000201 | 19
Danfoss © | 2020.07
Installation Guide
Danfoss ECdry Touch Kit
1�1
Laying the top floor
Please consult the floor manufacturer to
ensure that the floor covering is suitable for
floor heating. The final floor covering (lami-
nate or parquet) can be laid when the ECdry
heating system has been tested.
According to ISO 13732-2,
the comfortable floor sur-
face temperature depends
on the flooring material.
Soft wood (pine)
22.5 - 28°C
Hard wood (oak)
24.5 - 28°C
However, observe the maximum floor
surface temperature according to the floor-
ing manufacturer. For most wooden floor
products, the temperature is usually around
27 °C. All temperature settings must be set
some degrees higher to compensate for the
heat resistance in the top flooring.
Thermal
resistance
[m²K/W]
Examples of Flooring
Details
Approximate setting
for 25°C
floor temperature
0,07
11 mm HDF based laminate
> 800 kg/m³
28°C
0,10
14 mm beech parquet
650 - 800 kg/m³
31°C
0,13
22 mm solid oak plank
> 800 kg/m³
32°C
0.18
22 mm solid fir planks
450 - 650 kg/m³
35°C
1�1
Warning label
The warning label that is included in the
ECdry Touch Kit must be filled out and
placed in the distribution board. For future
reference it is important to fill in, which
room and how many ECdry elements that
have been installed, by whom and the
installation date. Furthermore, the room
should be drawn in the manual so it is easy
to see how the elements have been posi-
tioned in the room in the future. See layout
paper on next page.