6 | Danfoss © | 2020.07
AN324050550815en-000201
Installation Guide
Danfoss ECdry Touch Kit
The maximum thermal resistance be-
tween the ECdry element and the room is
0,18 m² K/W as shown in the table below.
The ECdry floor heating system is for indoor ap-
plications in dry rooms only. As with any other
underfloor heating system, it will be most
effective if the underfloor is well insulated.
The following directions will guide you step-
by-step through the installation process. Please
read the directions and the safety precautions
before you start the installation process.
Thermal
resistance
Examples of Flooring
Density
0,07 m² K/W
11 mm HDF based laminate
>800 kg/m³
0,10 m² K/W
14 mm beech parquet
650-800 kg/m³
0,13 m² K/W
22 mm solid oak plank
>800 kg/m³
0,18 m² K/W
22 mm solid fir planks
450-650 kg/m³