DEVIreg™ 132
Installation Guide
9
2. Fasten the thermostat directly to the wall by driving
the screws through the holes in each side of the
thermostat.
= Screw holes for fastening the thermostat.
3.
Connect the thermostat according to the connection
diagram.
IP30
0T30
D132
NTC
1
2
3
4
Sensor
Max.Load
16 (1) A
Mains
220-240V~
N
LOAD
L
LOAD
N L
The screen of the heating cable must be connected
via a connector together with the earth conductor of
the power supply cable.
Note:
Always install the floor sensor in a conduit in
the floor.