DEVIreg™ 132
Installation Guide
4
1.1
Technical Specifications
Operation voltage
220-240 V~, 50 Hz
Standby power consumption
Max 5W
Relay:
Resistive load
Inductive load
Max 16 A / 3680 W @ 230 V
cos φ= 0.3 max 1 A
Sensing units
NTC 15 kOhm at 25 °C
Sensing values:
0 °C
25 °C
50 °C
42 kOhm
15 kOhm
6 kOhm
Hysteresis
± 0,2 °C
Ambient temperature
0 to +30 °C
Frost protection temperature
5 °C -
Temperature range
5-35 °C room temperature
20-50 °C floor temperature
limiter - default 35 °C
Cable specification max
1 x 4 mm² or 2 x 2,5 mm²
Ball pressure temperature
75 °C
Pollution degree
Degree 2 (domestic use)
Type
1C
Storage temperature
-20 to +65 °C
IP class
30
Protection class
Class II -