10.
When should the
pistons be replaced
This section provides guidance on, how to
determine whether the parts of the pump are
worn and should be replaced. In case of doubt
- the pistons must be replaced. The pictures
below are meant as a guideline for evaluating
the wear of the sliding surface.
Note: If the pistons break down, the pump will
suffer a disastrous breakdown.
Picture 1:
Cavitation of the piston shoes.
New inspection is required in 3,000-4,000 hours.
Picture 2:
Cavitation of the piston shoes.
All pistons must be replaced within the next
500-1,000 hours.
Picture 3:
Cavitation of the piston shoes.
All pistons must be replaced within the next
100-200 hours.
Picture 4:
Abrasive wear of the piston shoes.
All pistons must be replaced immediately.