![background image](http://html1.mh-extra.com/html/danfoss/app-s-674-2-0-3-5/app-s-674-2-0-3-5_disassembling-and-assembling-instructions_3587195015.webp)
Instruction
Disassembling and assembling APP S 674 2.0-3.5
15
180R9281 / 521B1275 / DKCFN.PI.013.C3.02 / 05.2013
1.
Carefully lift valve plate assembly free with
the aid of a screwdriver.
5.
Disassembling and
assembling of cylinder
barrel and valve plate
3.
Mount the new back-up rings on the valve
plate. Then mount the O-rings.
Backup-ring
O-ring
4.
Lubricate the new O-rings/back-up rings
and the liners in the cylinder barrel with
clean filtred water.
2.
Replace O-rings and back-up rings on valve
plate.
O-ring
Backup-
ring
5.
Carefully press, by hand, valve plate onto
cylinder barrel. The cylinder barrel is now
ready for mounting.