Service guide
|
Disassembling and Assembling, APP 11-13 and APP 16-22
© Danfoss | DCS (im) | 2017.06
16 | 180R9228 | 521B1181 | DKCFN.PI.013.V3.02
5. Replace the O-ring on mounting flange.
6. Carefully insert the swash plate into the
housing.
7. Mount the 3 screws as shown below. Turn
each screw a couple of rounds at the time,
to ensure the swash plate is pulled as
straight forward as possible.
Note: Be careful not to squeeze/damage
the O-ring.
8. Insert the remaining screws and cross
tighten them according to exploded view.
9. Connect the pump to the rest of the
system. Bleed the pump.
Follow the start-up procedures, see
instruction 180R9223.